To obtain a quote please select the checkbox next to a part number. You can scroll through the catalog or quickly jump around the various pole configurations by using the Navigate Pole menu on the left. Once you have made all of your selections, simply click the Finish Request button located in the Navigate Pole menu. This will bring you to a tiny form to fill out at the bottom of the page.
ONE POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-01-A 1-pole: 1 1-pole block of a Front-Connected W3TS Switch with (1) Single-pole Basic with Red Handle(Element #1), Barriers, 600 Volt 30 amp.
W3TS-01-A & C 1-pole: 1 Cover 1-pole block of a Front-Connected W3TS Switch consisting of (1) Single-pole Basic with a Red Handle (Element #1), Barriers, Cover, 600 Volt 30 amp.
W3TS-01-A-B 1-pole: B1 Cover 1-pole block of a Back-Connected W3TS Switch consisting of (1) Single-pole Basic with Red Handle (Element #1), Barriers, Cover, 600 Volt 30 amp.
W3TS-01-A-DR 1-pole: 1 DR 1-pole block of a Front-Connected W3TS Switch with (1) Element #1 Single-pole Basic with Red Handle (Element #1), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-01-A-DR & C 1-pole: 1 DR C 1-pole block of a Front Connected W3TS Switch consisting of (1) Single-pole Basic with Red Handle (Element #1), Barriers, Cover, DIN Rail Clips, 600 Volt 30 amp.
W3TS-01-Ak 1-pole: 1k 1-pole block of a Front-Connected W3TS Switch consisting of (1) Single-pole Basic with Black handle (Element 1k), Barriers, 600 Volt 30 amp.
W3TS-01-Ak & C 1-pole: 1k C 1-pole block of a Front-Connected W3TS Switch consisting of (1) Single-Pole Basic with Black Handle (Element 1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-01-Ak-B 1-pole: B1k C 1-pole block of a Back-Connected W3TS Switch consisting of (1) Single-pole Basic with Black handle (Element 1k), Barriers, Cover, 600 Volt 30 amp.
W3TS-01-Ak-DR 1-pole: 1k DR 1-pole block of a Front-Connected W3TS Switch with (1) Single-pole Basic switch with Black Handle(Element# 1k), Barriers, DIN Rail clips, 600 Volt 30 amp.
W3TS-01-Ak-DR&C 1-pole: 1k DR C 1-pole block of a Front-Connected W3TS Switch consisting of (1) Single-pole Basic with Black Handle (Element 1k), Barriers, Cover, DIN Rail Clips, 600 Volt 30 amp.
W3TS-01-B 1-pole: 7 1-pole block of a Front-Connected W3TS Switch consisting of (1) Test Jack Switch with Black Handle (Element #7), Barriers, 600 Volt 30 amp.
W3TS-01-Br 1-pole: 7r 1-pole block of a Front-Connected W3TS Switch consisting of (1) Test Jack Switch with Red Handle (Element #7r), Barriers, 600 Volt 30 amp.
W3TS-01-F&C 1-pole: 7 C 1-pole block of a Front-Connected W3TS Switch consisting of (1) Test Jack Switch with Black Handle (Element #7), Barriers, Cover, 600 Volt 30 amp.
TWO POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-02-A 2-pole 1/1 2-pole block of Front-Connected W3TS Switches with 2 Single-pole Basics with Red Handles (Element #1), Barriers, 600 Volt 30 amp.
W3TS-02-A & C 2-pole 1/1 C 2-pole block of Front-Connected W3TS Switches with 2 Single-pole Basics with Red Handles (Element #1) separated by an Insulating Barrier, Cover, 600 Volt 30 amp.
W3TS-02-A-B 2-pole B1/B1 C 2-pole block of Back-Connected W3TS Switches consisting of (2) basic Single-pole Switches with Red Handles (Element #1), Cover, 600 Volt 30 amp.
W3TS-02-A-DR 2-pole 1/1 DR 2-pole block of Front-Connected W3TS Switches with two Single-pole Basic Switches with Red handles (Element #1), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-02-A-DR & C 2-pole 1/1 DR C 2-pole block of Front-Connected W3TS Switches with two Single-pole Basics with Red Handles (Element #1), Barriers, DIN Rail clips, Cover, 600 Volt 30 amp.
W3TS-02-Ak 2-pole 1k/1k 2-pole block of Front-Connected W3TS Switches with two Single-pole Basics with Black Handles (Element 1k), Barriers, 600 Volt 30 amp.
W3TS-02-Ak & C 2-pole:1k/1k C 2-pole block of Front-Connected W3TS Switches with 2 Single-pole Basics with Black Handles (Element 1k), Barriers, Cover, 600 Volts 30 amp.
W3TS-02-Ak-DR 2-pole: 1k/1k DR 2-pole block of W3TS Front-Connected Switches with (2) Single-pole Basics with Black Handles (Element #1k), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-02-Akr 2-pole: 1k/1r 2-pole block of Front-Connected W3TS Switches with (1) Basic Switch with Black handle (Element #1k), and (1) Basic Switch with Red handle (Element #1), Barriers, 600 Volt 30 amp.
W3TS-02-B 2-pole: 2 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic Switches with Red handles (Element #2), Barriers, 600 Volt 30 amp.
W3TS-02-B-DR 2-pole: 2 DR 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic Switches with Red Handles (Element #2), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-02-B-DR&C 2-pole: 2 DR C 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic Switches with Red Handles (Element #2), Barriers, DIN Rail Clips, Cover, 600 Volt 30 amp.
W3TS-02-Bk 2-pole: 2k 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic Switches with Black handles (Element 2k), Barriers, 600 Volt 30 amp.
W3TS-02-Bk&C 2-pole: 2k C 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic with Black handles (Element 2k), Barriers, Cover, 600 Volt 30 amp.
W3TS-02-Bk-DR 2-pole: 2k DR 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basics with Black Handles (Element 2k), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-02-Bk-DR&C 2-pole: 2k DR C 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic with Black Handles (Element 2k), DIN Rail Clips, Cover, 600 Volt 30 amp.
W3TS-02-Brk 2-pole: 2rk 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basic with 1 Red & 1 Black handle, barriers, 600 Volt 30 amp.
W3TS-02-Brk&C 2-pole: 2rk C 2-pole block of Front-Connected W3TS Switches consisting of Ganged Double-pole Basics with 1 Red & 1 Black handle, Barriers, Cover, 600 Volt 30 amp.
W3TS-02-C 2-pole: 9 2-pole block of Front-Connected W3TS Switches with a Right Hand Current Assembly with Test Jack and Short-Circuiting Current Assemblies and Common Bar, Black Handles (Element #9), 600 Volt 30 amp.
W3TS-02-C&C 2-pole: 9 C 2-pole block of Front-Connected W3TS Switches with Right Hand Current Assembly with Test Jack and Short-Circuiting Current Assemblies and Common Bar, Black Handles (Element #9), Cover, 600 Volt 30 amp.
W3TS-02-C-DR 2-pole: 9 DR 2-pole block of Front-Connected W3TS Switches with Right Hand Current Assembly with Test Jack and Short-Circuiting Current Assemblies and Common Bar, Black Handles (Element #9); DIN Rail Clips; 600 Volt 30 amp.
W3TS-02-E 2-pole 5 2-pole block of Front-Connected W3TS Switches consisting of a Ganged Two-Pole Short-Circuiting Current Assembly with Common Bar, Black Handles (Element #5); 600 Volt 30 amp.
W3TS-02-E&C 2-pole: 5 C 2-pole block of Front-Connected W3TS Switches consisting of Ganged Two-Pole Short-Circuiting Current Assembly with Common Bar, Black Handles (Element #5); Cover; 600 Volt 30 amp.
W3TS-02-E-DR 2-pole: 5 DR 2-pole block of Front-Connected W3TS Switches with Ganged Short-Circuiting Current Assembly and Common Bar, Black Handles (Element #5) ; DIN Rail Clips; 600 Volt 30 amp.
W3TS-02-Er 2-pole: 5r 2-pole block of Front-Connected W3TS Switches with Ganged Short-Circuiting Current Assembly and Common Bar and Red Handles (Element #5r); 600 Volt 30 amp.
W3TS-02-Er-DR 2-pole: 5r DR 2-pole block of Front-Connected W3TS Switches with Ganged 2-pole Short-Circuiting Current Assembly and Common Bar with Red Handles (Element 5r); DIN Rail Clips; 600 Volt 30 amp.
W3TS-02-F & C 2-pole: 8 C 2-pole block of Front-Connected W3TS Switches with Left Hand Current Assembly, Test Jack and Short-Circuiting Current Assembly and Common Bar with Black Handles(Element #8); Cover; 600 Volt 30 amp.
W3TS-02-F 2-pole: 8 2-pole block of Front-Connected W3TS Switches with Left Hand Current Assembly and Test Jack and Short-Circuiting Current Assemblies and Common Bar with Black Handles (Element #8); 600 Volt 30 amp.
W3TS-02-F-B 2-pole: B8 C 2-pole block of Back-Connected W3TS Switches consisting of (1) Left Hand Current Assembly with Test Jack and Short-Circuiting Current Assemblies and Common Bar with Black Handles (Element #8); Cover; 600 Volt 30 amp.
W3TS-02-F-DR 2-pole: 8 DR 2-pole block of Front-Connected W3TS Switches with Left Hand Current Assembly consisting of Test Jack and Short-Circuiting Current Assemblies and Common Bar with Black Handles (Element #8); DIN Rail Clips; 600 Volt 30 amp.
W3TS-02-Fr2&C 2-pole: 9r C 2-pole block of Front-Connected W3TS Switches consisting of a Right-Hand Current Assembly with Test Jack & Short-Circuit Current Assembly and Common Bar with Black Handles (Element #9) with Red Handles; Cover; 600 Volt 30 amp.
W3TS-02-K 2-pole: 11 2-pole block of Front-Connected W3TS Switches with Left-Hand Single Terminal and Short-Circuiting Assembly connected by Common Bar; Black Handles (Element #11); 600 Volt 30 amp.
W3TS-02-K&C 2-pole: 11 C 2-pole block of Front-Connected W3TS Switches with Left-Hand Single Terminal and Short-Circuiting Assembly connected by Common Bar with Black Handles (Element #11); Cover; 600 Volt 30 amp.
W3TS-02-K-DR&C 2-pole: 11 DR C 2-pole block of Front-Connected W3TS Switches with Left-Hand Single Terminal and Short-Circuiting Assembly connected by Common Bar with Black Handles(Element #11); Cover; DIN Rail Clips; 600 Volt 30 amp.
W3TS-02-T 2-pole 9 2-pole block of Front-Connected W3TS Switches with (Right-Hand Current Assembly with Test Jack & Short-Circuit Current Assembly; Common Bar with Ganged Black Handles (Element #9); 600 Volt 30 amp.
W3TS-02-TS-D 2-pole: 12 2-pole block of W3TS Front-Connected Short-Circuiting switch followed by a Single Terminal and connected by Common Bar with Black Handles (Element #12); Barriers; 600 Volts 30 amp.
W3TS-02-TS2 2-pole: 7/7 2-pole block of Front-Connected W3TS Switches with (2) Element #7 (Test Jack Switches) separated by Barriers; Black Handles; 600 Volts 30 amp.
W3TS-02-TS8-DR 2-pole: 13/13 DR 2-pole block of Front-Connected Switches consisting of (2) Through Bar Switches (Element #13), Barriers, Din Rail Clips; 600 Volts 30 amp.
W3TS-02-TS2&C 2-pole: 7/7 C 2-pole block of Front-Connected W3TS Switches with (2) Element #7 (Test Jack Switches) separated by Barriers, Black Handles, Cover; 600 Volts 30 amp.
THREE POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-03-A 3-pole: 1/1/1 3-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles, Barriers, 600 Volt 30 amp.
W3TS-03-A&C 3-pole: 1/1/1 C 3-pole block of Front-Connected W3TS test Switches consisting of (3) Single-Pole Basics with Red Handles (Element #1), Barriers, Cover, 600 Volt 30 amp.
W3TS-03-A-B 3-pole: B1/B1/B1 3-pole block of Back-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles (Element #1) Barriers, Cover, 600 Volt 30 amp.
W3TS-03-A-DR 3-pole: 1/1/1 DR 3-pole block of Front-Connected W3TS Switches with (3) Basic Switches with Red Handles (Element #1), Barriers, and DIN Rail Clips, 600 Volt 30 amp.
W3TS-03-A-DR&C 3-pole: 1/1/1 DR C 3-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles, Barriers, DIN Rail Clips, Cover, 600 Volt 30 amp.
W3TS-03-Ak 3-pole: 1k/1k/1k 3-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Black Handles (Element #1k), Barriers, 600 Volt 30 amp.
W3TS-03-Ak-B 3-pole: B1k/B1k/B1k C 3-pole block of Back-Connected W3TS Switches with (3) Single-Pole Basics with Black Handles (Element #1k), Barriers, & Cover, 600 Volt 30 amp.
W3TS-03-Ak-DR 3-pole: 1k/1k/1k DR 3-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basic Switches with Black Handles (Element #1k), Barriers, DIN Rail Clips, rated 600 Volt 30 amp.
W3TS-03-Ak-DR&C 3-pole: 1k/1k/1k DR C 3-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Black Handles (Element 1k), Barriers, DIN Rail Clips, Cover, rated 600 Volt 30 amp.
W3TS-03-B & C 3-pole: 1/9 C 3-pole block of Front-Connected W3TS Switches with Single-Pole Basic (Element #1), Red Handle, and Right-Hand Current Assembly with Test Jack & Short Circuit Current Assembly with Common Bar (Element #9), Black Handles, Cover, 600 Volt 30 amp.
W3TS-03-B-B 3-pole: B1/B9 C 3-pole block of Back-Connected W3TS Switches with a Single-Pole Basic (Element #1) - Red Handle, and Right-Hand Current Assembly with Test Jack & Short Circuit Current Assembly with Common Bar (Element #9), Black Handles, Barriers, Cover, 600 Volt 30 amp.
W3TS-03-B-DR & C 3-pole: 1/9 DR C 3-pole block of Front-Connected W3TS Switches with Single-Pole Basic with Red Handle (Element #1), and Right-Hand Current Assembly with Test Jack & Short Circuit Current Assembly with Common Bar (Element #9), Black Handles, Barriers, DIN Rail Clips, Cov
W3TS-03-Bk 3-pole: 1k/9 3-pole block of Front-Connected W3TS Switches with Basic Black Handle (Element #1k) and Right-Hand Current Assembly with Test Jack and Short Circuit Current Assembly with Common Bar, Black Handles, Barriers, 600 Volt 30 amp.
W3TS-03-Bk-B 3-pole: B1k/B9 3-pole block of Back-Connected W3TS Switches with Black Single-Pole Basic (Element #1) - Red Handle, and Right-Hand Current Assembly with Test Jack & Short Circuit Current Assembly with Common Bar (Element #9) - Black Handles, Barriers, Cover, 600 Volt 3
W3TS-03-C 3-pole: 9/1 3-pole block of Front-Connected W3TS Switches with Right-Hand Current Assembly with Test Jack & Short Circuit Current Assembly with Common Bar (Element #9) - Black Handles and a Single-Pole Basic (Element #1) - Red Handle, Barriers, 600 Volt 30 amp.
W3TS-03-D 3-pole: 3 3-pole block of Front-Connected W3TS Switches consisting of a Ganged Three-Pole Basic with Red Handles (Element #3), Barriers, 600 Volt 30 amp.
W3TS-03-D&C 3-pole: 3 C 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Basic Switches with Red Handles, (Element #3), Barriers, Cover, 600 Volt 30 amp.
W3TS-03-D-B 3-pole: B3 C 3-pole block of Back-Connected W3TS Switches consisting of Ganged Three-Pole Basic Switches with Red Handles (Element #3), Barriers, Cover, 600 Volt 30 amp.
W3TS-03-D-DR 3-pole: 3 DR 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Basic Switches with Red Handles (Element #3), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-03-D-DR&C 3-pole: 3 DR C 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Basic Switches with Red Handles (Element #3), Barriers, DIN Rail Clips, Cover, 600 Volt 30 amp.
W3TS-03-Dk 3-pole: 3k 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Basics Switches with Black Handles (Element 3k); Barriers; 600 Volt 30 amp.
W3TS-03-Dk-DR 3-pole: 3k DR 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Basic Switches with Black Handles (Element 3k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-03-Dk-DR&C 3-pole: 3k DR C 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Basic Switches with Black Handles (Element #3k); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-03-E 3-pole: 6 3-pole block of Front-Connected W3TS Switches consisting of Ganged Three-Pole Short-Circuiting Current Assembly with Common Bar, Black Handles (Element #6); Barriers; 600 Volt 30 amp.
W3TS-03-E&C 3-pole: 6 C 3-pole block of Front-Connected W3TS Switches consisting of a Ganged Three-Pole Short-Circuiting Current Assembly with Common Bar, Black Handles (Element #6); Barriers; Cover; 600 Volt 30 amp.
W3TS-03-E-ST&C 3-pole: 6 C 3-pole block of Front-Connected W3TS Switches with Ganged 3-Pole Short-Circuit Current Assembly with Common Bar, Black Handles (Element #6); Barriers; Cover; 600 Volt 30 amp.
W3TS-03-Er & C 3-pole: 6r C 3-pole block of Front-Connected W3TS Switches consisting of a Ganged Three-Pole Short-Circuiting Current Assembly with Common Bar, Red Handles (Element #6r); Barriers; Cover; 600 Volt 30 amp.
W3TS-03-Er 3-pole 6r: w/red Handles 3-pole block of Front-Connected W3TS Switches with Ganged Three-Pole Short-Circuiting Current Assembly with Common Bar, Red Handles (Element #6r); Barriers; 600 Volt 30 amp.
W3TS-03-F 3-pole: 7/7/7 3-pole block of Front-Connected W3TS Switches with (3) Element #7 (Test Jack Switches), Black Handles; Barriers; 600 Volts 30 amp.
W3TS-03-F&C 3-pole: C 7/7/7 C 3-pole block of Front-Connected W3TS Switches with (3) Element #7 (Test Jack Switches), Black Handles, Barriers; Cover; 600 Volts 30 amp.
W3TS-03-F-DR 3-pole: 7/7/7 DR 3-pole block of Front-Connected W3TS Switches with (3) Element #7 (Test Jack Switches); Black Handles; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-03-Hk 3-pole: 5/1k 3-pole block of Front-Connected W3TS Switches with a Ganged 2-Pole Short-Circuit Current Assembly and Common Bar -Black Handles - (Element #5), and a Black Handled Single-Pole Basic (Element #1k); Barriers; 600 Volt 30 amp.
W3TS-03-Hk&C 3-pole: 5/1k C 3-pole block of Front-Connected W3TS Switches with a Ganged Two-Pole Short-Circuit Current Assembly and Common Bar (Element #5) - Black Handles, and a Black Handled Single-Pole Basic (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-03-K 3-pole: 4-4-4 3-pole block of Front-Connected W3TS Switches made up of (3) Short Circuiting Assemblies with Black Handles (Element #4), connected by a Common Bar; Barriers; 600 Volt 30 amp.
W3TS-03-K-DR 3-pole: DR 4-4-4 CB DR 3-pole block of Front-Connected W3TS Switches made up of (3) Short Circuiting Assemblies with Black Handles (Element #4), connected by a Common Bar; Barriers; DIN Rail; 600 Volt, 30 amp.
W3TS-03-M-B 3-pole: B1/B8 C 3-pole block of Back-Connected W3TS Switches with (1) Single Pole Basic with Black Handle(Element #1k) and (1) Left-Hand Short-Circuit & Test Jack Current Assembly with Common Bar - Black Handles (Element #8); Barriers; Cover; 600 Volt, 30 amp.
W3TS-03-Nk&C 3-pole: 14\1k\14 C 3-pole block of Front-Connected W3TS Switches with (1) Blank Space (Element #14), 1 Basic Switch with Black Handle (Element #1k), and 1 Blank Space (Element #14); Barriers; Cover; 600 Volt, 30 amp.
W3TS-03-P-DR 3-pole: 4/4/4 DR 3-pole block of Front-Connected W3TS Switches made up of (3) Short Circuiting Assemblies - Black Handles (Element #4); Barriers; DIN Rail; 600 Volt, 30 amp.
W3TS-03-TS-1-DR 3-pole: 4/4/4 CB DR 3-pole block of Front-Connected W3TS Switches consisting of (3) Short Circuiting Front-Connected Switches (Element #4) connected with Common Bar - Black Handles; Barriers; DIN Rail Clips; 600 Volt, 30 amp.
W3TS-03-TS-3 3-pole: 8/1 3-pole block of Front-Connected W3TS Switches with Left-Hand Current Assembly - Shorting, Test Jack & Common Bar - Black Handles (Element #8) plus a Single-Pole Basic with Red Handle (Element #1); Barriers; 600 Volt, 30 amp.
W3TS-03-TS8-DR 3-pole: 13/13/13 DR 3-pole block of Front-Connected W3TS Switches consisting of (3) Through Bars (Element #13); Barriers; Din Rail Clips; 600 Volts, 30 amp.
FOUR POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-04-A 4-pole: 1/1/1/1 4-pole block of Front-Connected W3TS Switches containing (4) Single-Pole Basics with Red Handles (Element #1), Barriers, 600 Volt 30 amp.
W3TS-04-A-B 4-pole: B1/B1/B1/B1 C 4-pole block of Back-Connected W3TS Switches with (4) Single-Pole Basic Switches with Red Handles (Element #1), Barriers, Cover, 600 Volts 30 amp.
W3TS-04-A-DR 4-pole: 1/1/1/1 DR 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Red Handles (Element #1), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-04-A-DR&C 4-pole: 1/1/1/1 DR C 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Red Handles (Element #1), Barriers, DIN Rail Clips, Cover, 600 Volt 30 amp.
W3TS-04-A-NK 4-pole 1/1/1/1 NK 4-pole block of Front-Connected W3TS Switches containing (4) Single-Pole NO SAFETY KNOB Basics with Red Handles (Element #1), Barriers, 600 Volt 30 amp.
W3TS-04-Ak & C 4-pole 1k/1k/1k/1k C 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element 1k), Barriers, Cover, 600 Volt 30 amp.
W3TS-04-Ak-B 4-pole: B B1k/B1k/B1k/B1k C 4-pole block of Back-Connected W3TS Switches with (4) Single-Pole Basic Switches with Black Handles (Element 1k), Barriers, Cover, 600 Volts 30 amp.
W3TS-04-Ak-DR 4-pole: 1k/1k/1k/1k DR 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element 1k), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-04-Ak-DR & C 4-pole 1k/1k/1k/1k DR C 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element #1k), Barriers, DIN Rail Clips, Cover, 600 Volt 30 amp.
W3TS-04-Akrkr & C 4-pole: 1k/1r/1k/1r C 4-pole block of Front-Connected W3TS Switches with all Single-Pole Basics with alternating Black & Red Handles, Barriers, Cover, 600 Volt 30 amp.
W3TS-04-C 4-pole 6/13 CB 4-pole block of Front-Connected W3TS Switches with Ganged Three-Pole Short-Circuiting Current Assembly - Black Handles (Element # 6) with 4-pole Common Bar joined to a Through Bar (element #13), Barriers, 600 Volt 30 amp.
W3TS-04-Dk&C 4-pole: 2k/2k C 4-pole block of Front-Connected W3TS Switches with (2) sets of Black Handled, Ganged, Double-Pole Basics (Element 2k), Barriers, Cover, 600 Volt 30 amp.
W3TS-04-Dk-DR&C 4-pole: 2k/2k DR C 4-pole block of W3TS Front-Connected W3TS Switches with 2 sets of Ganged Double-Pole Basics with Black Handles (Element 2k), Barriers, Cover, Din Rail Clips, 600 Volt 30 amp.
W3TS-04-Drk 4-pole: 2rk/2rk 4-pole block of Front-Connected W3TS Switches with (2) #2 Ganged Double-Pole Basics each pair having 1 Red Handle & 1 Black Handle (Element 2rk), Barriers, 600 Volt 30 amp.
W3TS-04-Drk-B 4-pole: B2rk/B2rk C 4-pole block of Back-Connected W3TS Switches with (2) Ganged Double-Pole Basics each pair with 1 Red Handle & 1 Black Handle (Element #2rk), Barriers, Cover, 600 Volt 30 amp.
W3TS-04-Drk-DR 4-pole: 2rk/2rk DR 4-pole block of Front-Connected W3TS Switches with (2) Ganged Double-Pole Basics each pair having 1 Red Handle & 1 Black Handle (Element 2rk), Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-04-E 4-pole 1/1/1/1 G 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element 1k), all ganged together, barriers, 600 Volt 30 amp.
W3TS-04-E-DR 4-pole: 1k/1k/1k/1k G DR 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element 1k), all Ganged together, Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-04-E-DR-G4 4-pole: 1/1/1/1 G DR 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Red Handles (Element #1), all Ganged together, Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-04-E-DR-G4-NK 4-pole: 1/1/1/1 NK G DR 4-pole block of Front-Connected W3TS NO SAFETY KNOB Switches with (4) Single-Pole Basics with Red Handles, (Element #1), all Ganged together, Barriers, DIN Rail Clips, 600 Volt 30 amp.
W3TS-04-Ek-DR-G4&C 4-pole: 1k/1k/1k/1k G DR C 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element 1k); all Ganged together; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-04-F 4-pole 1/1/9 4-pole block of Front-Connected W3TS Switches with (2) Single-Pole Basics with Red Handles (Element 1), and (1) Right-Hand Current Assembly with Test Jack & Short-Circuit Current Assembly - Black Handles - with Common Bar (Element #9); Barriers; 600 Volt
W3TS-04-H 4-pole: 5/5 4-pole block of Front-Connected W3TS Switches with (2) pair of Short-Circuiting Switches (Element #5), each pair ganged and connected by Common Bar; Barriers; 600 Volts 30 amp.
W3TS-04-J-DR 4-pole: 1/1/8 DR 4-pole block of Front-Connected W3TS Switches with 2 Basics with Red Handles (Element #1), and (1) Left-Hand Current Assembly with Test jack & Short-Circuit Current Assembly with Common Bar - Black Handles - (Element #8); Barriers; DIN Rail Clips; 600 Vo
W3TS-04-kA-DR 4-pole: 1k/1k/1k/1k DR 4-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Black Handles (Element 1k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-04-M 4-pole: 5/1/1 4-pole block of Front-Connected W3TS Switches with (1) Ganged Two-pole Short-Circuiting Current Assembly with Black Handles (Element #5), and (2) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volts 30 amp.
W3TS-04-P 4-pole 9/9 4-pole block of Front-Connected Switches with (2) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar - Black Handles -(Element #9); Barriers; 600 Volts 30 amp.
W3TS-04-R&C 4-pole: 7/7/7/7 C 4-pole block of Front-Connected W3TS Switches with (4) Current Test Jack Switches with Black Handles (Element #7); Barriers; Cover; 600 Volts 30 amp.
W3TS-04-R-DR 4-pole: 7/7/7/7 DR 4-pole block of Front-Connected W3TS Switches with (4) Current Test Jack Switches with Black Handles (Element #7); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-04-R-DR-G4 4-pole: 7/7/7/7 G DR 4-pole block of Front-Connected W3TS Switches with (4) Test Jack Switches with Black Handles (Element #7) ; all Ganged together; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-04-Rr-B 4-pole: B7r/B7r/B7r/B7r 4-pole block of Back-Connected W3TS Switches with (4) Current Test Jack Switches with Black Handles (Element #7); Barriers; Cover; 600 Volts 30 amp.
W3TS-04-TS&C 4-pole: 6/13 CB C 4-pole block of Front-Connected W3TS Switches with (1) Ganged 3-Pole Short-Circuit Current Assembly with Black Handles (Element #6), and 1 Through Bar (Element #13) all connected with Common Bar; Barriers; Cover; 600 Volts 30 amp.
W3TS-04-TS1&C 4-pole: 1k/1k/2rk C 4-pole block of Front-Connected W3TS Switches with (2) Single Pole Basics with Black Handles (Element 1k), and (1) Ganged Double-Pole Basic with 1 Black Handle & 1 Red Handle (Element 2rk); Barriers; Cover; 600 Volts 30 amp.
W3TS-04-TS10 4-pole: 4/4/4/4 G CB 4-pole block of Front-Connected W3TS Switches with (4) Short-Circuiting Switches (Element #4), all Ganged together and all connected by a Common Bar; Black Handles; End Barriers; 600 Volts 30 amp.
W3TS-04-TS2 4-pole: 4/4/4/4 4-pole block of Front-Connected W3TS miniature test Switches made up of (4) independent Short-Circuiting Switches (Element #4); Barriers; 600 Volts 30 amp.
W3TS-04-TS2-CB4DR-G4 4-pole: 4/4/4/4 G CB DR 4-pole block of Front-Connected W3TS Switches with (4) Short-Circuiting Switches with Black Handles (Element #4), all Ganged together, and all connected with a Common Bar; End Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-04-TS2-DR-G4 4-pole: 4/4/4/4 G DR 4-pole block of Front-Connected W3TS Switches with (4) Short-Circuiting Switches with Black Handles (Element #4), all Ganged together; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-04-TS3 4-pole: 4/4CB 4-pole block of Front-Connected W3TS Switches with (2) pair of double Short-Circuit Switches - Black Handles - (Element #4) with the second set having a 2-pole Common Bar; Barriers; 600 Volts 30 amp.
W3TS-04-TS4 4-pole: 1k/1k/2k 4-pole block Front-Connected W3TS Switches with (2) Single Pole Basics with Black Handles (Element 1k), and (1) Ganged Double-Pole Basic with Black Handles (Element 2k); Barriers; 600 Volts 30 amp.
W3TS-04-TS4-DR 4-pole: 1k/1k/2k DR 4-pole block of Front-Connected W3TS Switches with (2) Single Pole Basics with Black Handles (Element 1k), and (1) Ganged Double-Pole Basic with Black Handles (Element 2k); Barriers; DIN Rail Clips; 600 Volts 30amp.
W3TS-C-M04-U2 4-pole: 6/13 CB C 4-pole block of Front-Connected W3TS Switches consisting of a Ganged 3-pole Short-Circuit Assembly with Black Handles (Element #6) connected with a 4-Pole Common Bar to a Through Bar Switch (Element #13); End Barriers; Cover; 600 Volts 30 amp.
W3TS-04k-8 DR 4-pole 8/8 DR 4-pole block of Front-Connected W3TS Switches with 2 Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar - Black Handles - (Element #8); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-04-X-DR 4-pole: 6/7 DR 4-pole block of Front-Connected W3TS Switches containing (1) Ganged 3-pole Short-Circuit Current Assembly connected by Common Bar - Black Handles - (Element #6) to (1) Test Jack Switch with Black Handle (Element #7); Barriers; DIN Rail Clips; 600 Volt 30
W3TS-04-Wr&C-DR 4-pole: 9r/9r DR C 4-pole block of Front-Connected W3TS Switches with (2) Right-Hand Current Assembly with Test Jack & Short-Circuit Current Assembly with Common Bar & Red Handles (Element 9r); End Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-04-Wr&C 4-pole: 9r/9r C 4-pole block of Front-Connected W3TS Switches with (2) Right-Hand Current Assemblies with Test Jack (Element & Short-Circuit Current Assembly with Common Bar and Red Handles (Element 9R); End Barriers; Cover; 600 Volt 30 amp.
W3TS-04-TS9-DR 4-pole 2k/1/1 DR 4-pole block of Front-Connected W3TS Switches with (1) Ganged Double-Pole Basic with Black Handles (Element #2k), and (2) Single Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-04-TS8-DR 4-pole: 13/13/13/13 DR 4-pole block of Front-Connected W3TS Switches consisting of (4) Through Bar Switches (Element #13); Barriers; Din Rail clips; 600 Volts 30 amp.
W3TS-04-TS7-DR & C 4-pole: 2k/8 DR C 4-pole block of Front-Connected W3TS Switches with (1) Ganged 2-pole Basic with Black Handles (Element #2k), and (1) Left-Hand Current Assembly with Test Jack Switch & Short-Circuit Current Assembly with Common Bar - Black Handles (Element #8); Barriers;
W3TS-04-TS6 4-pole: 11/12 G 4-pole block of Front-Connected W3TS Switches with Left-Hand Single Terminal & Short-Circuit Current Assembly - Black Handles (Element #11) Ganged to a Right-Hand Single Terminal & Short-Circuit Assembly with Black Handles (Element #12); Barriers; 600 Vol
W3TS-04-TS5&C 4-pole: 7/1/7/1 C 4-pole block of Front-Connected W3TS Switches starting with a Test Jack Switch (Element #7) and alternating 1 for 1 with a Basic Switch with Red Handle (Element #1); Barriers; Cover; 600 Volts 30 amp.
FIVE POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-05-A 5-pole: 1/1/1/1/1 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Red Handles (Element #1), Barriers, 600 Volts 30 amp.
W3TS-05-A&C-DR 5-pole: 1/1/1/1/1 DR C 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Red Handles (Element #1), Barriers, DIN Rail Clips, Cover/ 600 Volts 30 amp.
W3TS-05-A&G 5-pole: 1/1/1/1/1 G 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Red Handles (Element #1), all Ganged together, Barriers, 600 Volts 30 amp.
W3TS-05-A-DR 5-pole: 1/1/1/1/1 DR 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Red Handles (Element #1), Barriers, DIN Rail Clips, 600 Volts 30 amp
W3TS-05-Ak 5-pole: 1k/1k/1k/1k/1k 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Black Handles (Element 1k), Barriers, 600 Volts 30 amp.
W3TS-05-Ak&C-DR 5-pole: 1k/1k/1k/1k/1k DR C 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Black Handles (Element 1k), Barriers, Cover, DIN Rail Clips , 600 Volts 30 amp.
W3TS-05-Ak-DR 5-pole: 1k/1k/1k/1k/1k DR 5-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Black Handles (Element 1k), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-05-K-B 5-pole: B7/B7/B7/B7/B7 C 5-pole block of Back-Connected W3TS Switches with 5 Test Jack Switches with Black Handles, (Element #7), Barriers, Cover, 600 Volts 30 amp.
W3TS-05-Kkkrr&C&Gred 5-pole: 7/8kr/12rG C 5-pole block of Front-Connected W3TS Switches with (1) Test Jack Switch (Element #7), (1) Left-Hand Test Jack Black Handle & Short-Circuit Red Handle Assembly with Common Bar (Element #8) and (1) Right-Hand Single Terminal & Short-Circuit Assembly with
W3TS-05-L-DR&C&Gred 5-pole: 8kr/12r/7 DR C 5-pole block of Front-Connected W3TS Switches with (1) Left-Hand Test Jack with Black Handle and Short-Circuit Red Handle Assembly with Common Bar (Element #8), (1) Right-Hand Single Terminal and Short-Circuit Red Handle Assembly with Common Bar (Element
W3TS-05-M 5-pole: 1/1/14/4 CB 5-pole block of Front-Connected W3TS Switches with (2) Single-Pole Red Basics with Red Handles (Element #1), (1) Blank Space (Element #14), and (2) Short Circuit Current Assembly Switches - Black Handles - (Elementa #4), connected with Common Bar, Barrier
W3TS-05-TS-B 5-pole: 1/1/14/5 5-pole block of Front-Connected W3TS Switches with (2) Single-Pole Red Basics (Element #1), (1) Blank Space (Element #14), and (1) Ganged Two-pole Short-Circuit Current Assembly with Common Bar - Black Handles (Element #5), Barriers, 600 Volts 30 amp.
W3TS-05-TS2 5-pole: 4/4/4/4/4 5-pole block of Front-Connected W3TS Switches made up of (5) independent Short-Circuiting Switches with Black Handles (Element #5), 600 Volts 30 amp.
W3TS-05-TS3 5-pole: 10/10/10/10/10 5-pole block of Front-Connected W3TS Switches consisting of (5) Single Terminal Switches (Element #10), Barriers, 600 volts 30 amp.
W3TS-05-TS4-B 5-pole: B15/B14/B14/B14/B15 C 5-pole block of Back-Connected W3TS Switches with (1) Terminal Block (Element #15), 3 Blank Spaces (Element #14), and (1) Terminal Block (Element #15), Barriers, Cover, 600 Volts 30 amp.
W3TS-05-TS5-DR 5-pole: 4/4/4/4/10 G DR 5-pole block of Front-Connected W3TS Switches with (4) Short-Circuiting Switches - Black Handles (Element #4), all Ganged together, and (1) Single Terminal (Element #10), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-05-TS6-DR 5-pole: 4/4/4/1/1 DR 5-pole block of Front-Connected W3TS Switches with (3) Short-Circuiting Switches - Black Handles - (Element #4), and (2) Basic Potentials with Red Handles(Element #1), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-05-TS6-DR&C 5-pole: C DR 4/4/4/1/1 5-pole block of Front-Connected W3TS Switches with (3) Short-Circuiting Currents - Black Handles -(Element #4), and (2) Basic Potentials with Red Handles (Element #1), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
SIX POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-06-A 6-pole: 1/1/1/1/1/1 6-pole block of Front-Connected W3TS Switches with (6) Single-Pole Basics with Red Handles (Element #1), Barriers, 600 Volts 30 amp.
W3TS-06-A&C 6-pole: 1/1/1/1/1/1 C 6-pole block of Front-Connected W3TS Miniature Test Switches with (6) Single-Pole Basics with Red Handles, Barriers, Cover, 600 Volts 30 amp.
W3TS-06-A-B 6-pole: B1/B1/B1/B1/B1/B1 C 6-pole block of Back-Connected W3TS test Switches with (6) Single-Pole Potential Basic Switches with Red Handles (Element #1), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-A-DR 6-pole: 1/1/1/1/1/1 DR 6-pole block of Front-Connected W3TS Test Switches with (6) Single-Pole Basics with Red Handles, Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-06-Ak-B 6-pole: B1k/B1k/B1k/B1k/B1k/B1k C 6-pole block of Back-Connected W3TS Switches with (6) Single-Pole Potential Basic Switches with Black Handles (Element 1k), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-Ak-DR & C 6-pole: 1k/1k/1k/1k/1k/1k DR C 6-pole block of Front-Connected W3TS Switches with (6) Single-Pole Basics with Black Handles (Element 1k), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
W3TS-06-Akrk-DR 6-pole: 1k/1/1k/1k/1k/1k DR 6-pole block of Front-Connected W3TS Switches with (1) Basic with Black Handle (Element #1k), (1) Basic with Red Handle (Element 1), and (4) Basics with Black Handles (Element 1k), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-06-Ark-DR 6-pole: 1/1/1/1k/1k/1k DR 6-pole block of Front-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), and (3) Basics with Black Handles (Element 1k), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-06-B-DR 6-pole: 5/5/5 DR 6-pole block of Front-Connected W3TS Switches made of (3) Ganged Two-Pole Short-Circuiting Assemblies with Common Bar - Black Handles - (Element #5), Barriers, DIN Rail clips, 600 Volts 30 amp.
W3TS-06-B-DR&C 6-pole: 5/5/5 DR C 6-pole block of Front-Connected W3TS Switches made of (3) Ganged Two-Pole Short-Circuiting Assemblies with Common Bars - Black Handles - (Element #5), DIN Rail clips, Cover, 600 Volts 30 amp.
W3TS-06-Br&C 6-pole: 5r/5r/5r C 6-pole block of Front-Connected W3TS Switches with (3) Ganged Two-Pole Short-Circuit Current Assemblies with Common Bar & Red Handles (Element #5r), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-Br-DR&C 6-pole: 5r/5r/5r DR C 6-pole block of Front-Connected W3TS Switches with (3) Ganged Two-Pole Short Circuit-Current Assemblies with Common Bar & Red Handles (Element #5r), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
W3TS-06-C 6-pole 9/9/9 6-pole block of Front-Connected W3TS Switches with (3) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bars - Black Handles -(Element #9), Barriers, 600 Volts 30 amp.
W3TS-06-C&C 6-pole: 9/9/9 C 6-pole block of Front-Connected W3TS Switches made up of (3) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #9), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-C-B 6-pole: B9/B9/B9 C 6-pole block of Back-Connected W3TS Switches with (3) Back-Connected Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #9), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-C-DR 6-pole: 9/9/9 DR 6-pole block of Front-Connected W3TS Switches made of (3) Right-Hand Test Jack & Short Circuit Current Assemblies with Common Bars and Black Handles (Element #9), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-06-CU 6-pole: 5/5/2 6-pole block of Front-Connected W3TS Switches with (2) Ganged Two-Pole Short-Current Assemblies with Common Bar & Black Handles (Element #5), and (1) Ganged Double Pole Basic with Red Handles (Element #2), Barriers, 600 Volts 30 amp
W3TS-06-CV 6-pole 1/1/13/1/1/13 6-pole block of Front-Connected W3TS Switches with (2) Single-Pole Basics - Red Handles (Element #1), (1)Through Bar (Element #13), (2) Single-Pole Basics with Red Handles (Element #1), and (1) Through Bar (Element #13),Barriers, 600 Volts 30 amp.
W3TS-06-K&C 6-pole: 8/8/8 C 6-pole block of Front-Connected W3TS Switches featuring (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Black Handles, Common Bar, (Element #8), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-K-B 6-pole: B8/B8/B8 C 6-pole block of Back-Connected W3TS Switches consisting of (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8), Barriers, Cover, 600 Volts 30 amp.
W3TS-06-TS8-B 6-pole: B2k/B2k/B8 C 6-pole block of Back-Connected W3TS Switches consisting of (2) Ganged 2-pole Basics with Black Handles (Element #2k) and a Left-Hand Test Jack/Short-Circuit Assembly with Common Bar and Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-06-TS7-B 6-p: B1k/B1/B1b/B7/B7r/B7b C 6-pole block of Back-Connected W3TS Switches consisting of (1) Basic with Black Handle (Element #1k), (1) Basic with Red Randle (Element 1), (1) Basic with Blue Handle (Element 1b), (1) Test Jack with Black Handle (Element #7), (1) Test Jack with Red Hand
W3TS-06-TS6-DR 6-pole: 13/13/13/13/13/13 DR 6-pole block of Front-Connected W3TS Switches consisting of (6) Through Bars (Element #13); Barriers; Din Rail clips; 600 Volts 30 amp.
W3TS-06-TS5&C-CB6-DR 6-pole: 4/4/4/4/4/13 CB DR 6-pole block of Front-Connected W3TS Switches with (5) Short-Circuiting Assembly Switches with Black Handles (Element #4) followed by (1) Through Bar (Element #13) and connected by a 6-pole Common Bar; Barriers; Din Rail Clips, Cover; 600 Volt 30 amp.
W3TS-06-TS4-DR 6-pole: 4/4/4/4/4/4 G DR 6-pole block of Front-Connected W3TS Switches with (6) independent Short-Circuit Current Switches with Red Handles (Element #4r); all ganged together; Barriers; DIN Rail Clips, 600 Volts 30 amp.
W3TS-06-TS3 6-pole: 4/4 G 4/4 G 4/4 G 6-pole block of Front-Connected W3TS Switches with (3) pairs of Short-Circuit Current Assemblies with Black Handles (Element #4) with each pair connected by a 2-pole Common Bar; Barriers; 600 Volt, 30 amp.
W3TS-06-TS2-DR&C 6-pole: 4/4/4/4/4/4 DR C 6-pole block of Front-Connected W3TS Switches made up of (6) independent Short-Circuiting Switches with Black Handles (Element #4); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-06-TS2-DR 6-pole: 4/4/4/4/4/4 DR 6-pole block of Front-Connected W3TS Switches made up of (6) independent Short-Circuiting Switches with Black Handles (Element #4); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-06-TS2 6-pole: 4/4/4/4/4/4 6-pole block of Front-Connected W3TS Switches made up of (6) independent Short-Circuiting Switches with Black Handles (Element #4); Barriers; 600 Volts 30 amp.
W3TS-06-T&C 6-pole: 1/1/1/4/4/4 C 6-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles (Element #1), and (3) Short-Circuit Current Switches with Black Handles (Element #4) Barriers; Cover; 600 Volts 30 amp.
W3TS-06-N&C 6-pole: 12/12/12 CB C 6-pole block of Front-Connected W3TS Switches featuring (3) Right-Hand Single Terminal & Short Circuit Current Assemblies with Black Handles (Element #12), all connected with 6-pole Common Bar; Barriers; Cover; 600 Volts 30 amp.
W3TS-06-M&C 6-pole: 1/1k/8/9 C 6-pole block of Front-Connected W3TS Switches with (1) Basic with Red Handle (Element #1), (1) Basic with Black Handle (Element #1k), (1) Left-Hand Current Assembly with Black Handles (Element #8), (1) Right-Hand Current Assembly with Test Jack and Short
W3TS-06-K-DR&C 6-pole: 8/8/8 DR C 6-pole block of Front-Connected W3TS Switches Consisting of (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-06-K-DR 6-pole: 8/8/8 DR 6-pole block of Front-Connected W3TS Switches consisting of (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8); Barriers; DIN Rail Clips; 600 Volts 30 amp.
SEVEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-07-A & C 7-pole, 1/1/1/1/1/1/1 C 7-pole block of Front-Connected W3TS Single-Pole Basic Switches with Red Handles (Element #1), Barriers, Cover, 600 Volts 30 amp.
W3TS-07-A-DR 7-pole: 1/1/1/1/1/1/1 DR 7-pole block of Front-Connected W3TS Single-Pole Basic Switches with Red Handles (Element #1), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-07-Ak-DR 7-pole: 1k/1k/1k/1k/1k/1k/1k DR 7-pole block of Front-Connected W3TS Switches with (7) Single-Pole Basics with Black Handles (Element #1k) , Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-07-Ak-DR & C 7-pole: 1k/1k/1k/1k/1k/1k/1k DR C 7-pole block of Front-Connected W3TS Single-Pole Basic Switches with Black Handles (Element 1k), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
W3TS-07-C 7-pole: 1/1/1/9/9 7-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles (Element #1), and (2) Right-Hand Current Assemblies of Test Jack & Short-Circuit Current Assemblies with Common Bar - Black Handles - (Element #9), Barriers, 600 Volts 30 amp.
W3TS-07-K&C 7-pole: 1/9/1/9/1 C 7-pole block of Front-Connected W3TS Switches consisting of (3) Single-Pole Basics with Red Handles (Element #1), and (2) Right-Hand Current Assemblies of Test Jack & Short-Circuit Current Assemblies with Common Bar - Black Handles, Barriers, Cover, 600 Volts 30 amp.
W3TS-07-S & C 7-Pole: 4/4/4/4/4/4/13 CB C 7-pole block of Front-Connected W3TS Switches with (6) Short-Circuiting Assemblies with Black Handles (Element #4), Ganged in Pairs followed by (1) Through Bar Switch (Element #13), and all Connected with a 7-pole Common Bar, End Barriers, Cover, 600 Volt 30 amp.
W3TS-07-T 7-pole: 5/3/2 7-pole Black of Front-Connected W3TS Switches with (1) Ganged 2-pole Short-Circuit Assembly with Common Bar - Black Handles - (Element #5), (1) Ganged 3-pole Basic with Red Handles (Element #3), and (1) Ganged 2-pole Basic with Red Handles (Element #2), Barriers, 600 Volts 30 amp.
W3TS-07-TPC 7-pole: 5/5/3 7-pole block of Front-Connected W3TS Switches with (2) Ganged 2-pole Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #5), and (1) Ganged 3-pole Basic with Red Handles (Element #3), Screw Terminal Assembly, Barriers, 600 Volts 30 amp.
W3TS-07-TS-Ak&C 7-pole: 1k/1k/1k/1k/1k/9 C 7-pole block of Front-Connected W3TS Switches with (5) Single-Pole Basics with Black Handles (Element 1k), and (1) Right-Hand Test Jack & Short-Circuit Current Assembly with Common Bar & Black Handles (Element #9), Barriers, Cover, 600 Volts 30 amp.
W3TS-07-TS2-DR 7-pole: 1/1/1/14/1/1/1 DR 7-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles (Element #1), (1) Blank Space (Element #14), and (3) Single-Pole Basics with Red Handles (Element #1), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-07-TS4 & C 7-pole: 3/8/8 C 7-pole block of Front-Connected W3TS Switches with (1) Ganged 3-pole Basics with Red Handles (Element #3), (2) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8), Barriers, Cover, 600 Volts 30 amp.
W3TS-07-TS4-DR & C 7-pole: 3/8/8 DR C 7-pole block Front-Connected W3TS Switches with (1) Ganged 3-pole Basic with Red Handles (Element #3), and (2) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
W3TS-07-TS5-B 7-pole B8/B14/B14/B14/B9 C 7-pole block of Back-Connected W3TS Switches with (1) Left Hand Test Jack/Short-Circuit Current Assembly with Common Bar and Black Handles (Element #8), (3) Blank Spaces (Element #14), and (1) Right-Hand Test Jack and Short-Circuiting Current Assembly with Common Bar and Black Handles (Element #9), Barriers, Cover, 600 Volt 30 Amp.
W3TS-07-TS6-DR & C 7-pole: 8/8/8/13 DR C 7-pole block Front-Connected W3TS Switches with (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8), and (1) Through Bar Switch(Element #13), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
W3TS-07-TS7-DR & C 7-pole: 5/5/5/13 DR C 7-pole block of Front-Connected W3TS Switches with (3) Ganged 2-pole Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #5), and (1) Through Bar Switch (Element #13), Barriers, DIN Rail Clips, Cover, 600 Volts 30 amp.
W3TS-07-TS8-B 7-pole: B5/B5/B5/B1 7-pole block of Back-Connected W3TS Switches with (3) Ganged 2-pole Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #5), and (1) Basic with Red Handle (Element #1), Barriers, Cover, 600 Volts 30 amp.
W3TS-07-TS9-CB4&3-DR 7-pole: 7-7-7-7 CB 7-7-7 CB DR 7-pole block of Front-Connected W3TS Switches with (4) Test Jacks with Black Handles (Element #7) and with 4-pole Common Bar, and (3) Test Jacks with 3-pole Common Bar and Black Handles (Element #7), Barriers, DIN Rail Clips, 600 Volts 30 amp.
W3TS-07-V&C 7-pole: 1/1K/1K/1K/1K/1K/1K C 7-pole block of Front-Connected W3TS Switches with (1) Basic with Red Handle (Element #1), and (6) Basics with Black Handle (Element 1k), Barriers, Cover, 600 Volts 30 amp.
EIGHT POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-08-A-DR 8-pole: 1/9/1/1/8/1 DR 8-pole block of Front-Connected W3TS Switches with 1 Basic with Red Handle (Element #1), (1) Right-Hand Current Assembly with Black Handles (Element #9), 2 Basics with Red Handles (Element #1), (1) Left-Hand Current Assembly with Black Handles (Element #8), and (1) Basic with Red Handle (Element #1); Din Rail Clips; 600 Volts 30 amp.
W3TS-08-D 8-pole: 1/1/1/1/1/1/1/1 8-pole block of Front-Connected W3TS Switches containing (8) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volts 30 amp.
W3TS-08-D&C 8-pole: 1/1/1/1/1/1/1/1 C 8-pole block of Front-Connected W3TS Switches containing (8) Single-Pole Basics with Red Handles (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-08-D&C-DR 8-pole: 1/1/1/1/1/1/1/1 DR C 8-pole block of Front-Connected W3TS Switches with (8) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-08-D&G 8-pole 1/1/1/1/1/1/1/1 G 8-pole block of Front-Connected W3TS Switches consisting of (8) Single-Pole Basics with Red Handles (Element #1), all Ganged together; Barriers; 600 Volts 30 amp.
W3TS-08-D-CB8-G8 8-pole: 1/1/1/1/1/1/1/1 G CB 8-pole block of Front-Connected W3TS Switches with (8) Single-Pole Basics with Red Handles (Element #1), all Ganged together and connected by an 8-pole Common Bar; End Barriers; 600 Volts 30 amp.
W3TS-08-D-DR 8-pole: 1/1/1/1/1/1/1/1 DR 8-pole block of Front-Connected W3TS Switches containing (8) Single-Pole Basics with Red Handles (Element #1); Barriers; Din Rail Clips; 600 Volts 30 amp.
W3TS-08-Dk&C-DR 8-pole: 1k/1k/1k/1k/1k/1k/1k/1k DR C 8-pole block of Front-Connected W3TS Switches with (8) Single-Pole Basics with Black Handles (Element #1k); Barriers; Cover; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-Dk-DR 8-pole: 1k/1k/1k/1k/1k/1k/1k/1k DR 8-pole block of Front-Connected W3TS Switches with (8) Single-Pole Basics with Black Handles (Element 1k); Barriers; Din Rail clips; 600 Volts 30 amp.
W3TS-08-L-B 8-pole: B9/B9/B9/B1/B1 C 8-pole block of Back-Connected W3TS Switches with (3) Right-Hand Test Jack and Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Red Handle Basics (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-08-Lk-DR 8-pole: 9/9/9/1k/1k DR 8-pole block of Front-Connected W3TS Switches with (3) Right-Hand Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Black Handled Basics (Element #1k); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-N-B 8-pole: B5/B5/B5/B1/B1 C 8-Pole Block of Back-Connected W3TS Switches with (3) Ganged 2-pole Short-Circuiting Assemblies with Common Bar and Black Handles (Element #5), followed by (2) Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp.
W3TS-08-P 8-pole: 9/9/9/9 8-pole block of Front-Connected W3TS Switches with (4) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #9);Barriers; 600 Volts 30 amp.
W3TS-08-P&C -DR 8-pole: 9/9/9/9 DR C 8-pole block of Front-Connected W3TS Switches with (4) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-08-P&C 8-pole: 9/9/9/9 C 8-pole block of Front-Connected W3TS Switches with (4) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-08-P-B 8-pole: B9/B9/B9/B9 C 8-pole block of Back-Connected W3TS Switches with (4) Right-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #9);Barriers; Cover; 600 Volts 30 amp.
W3TS-08-Srk 8-pole: 2rk/2rk/2rk/2rk 8-pole block of Front-Connected W3TS Switches with (4) Ganged Double-Pole Basics with 1 Red Handle & 1 Black Handle (Element #2rk); Barriers; 600 Volts 30 amp.
W3TS-08-TS-A-DR 8-pole:7/7/7/7/7/7/7/7 DR 8-pole block of W3TS Front-Connected W3TS Switches made up of (8) Test Jacks with Black Handles (Element #7); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS-Dk-DR 8-pole: 1k/1k/1k/1k/1k/1k/1k/1k CB DR 8-pole block of Front-Connected W3TS Switches with (8) Single-Pole Basics with Black Handles (Element #1k) connected with a Common Bar; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS-Dk-DR 8-pole: 1k/1k/1k/1k/1k/1k/1k/1k CB DR 8-pole block of Front-Connected W3TS Switches with (8) Single-Pole Basics with Black Handles (Element #1k) connected with a Common Bar; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS10-DR 8-pole: 8/8/8/1kU/1kU DR 8-pole block of Front-Connected W3TS Switches with (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar and Black Handles (Element #8), and (2) Basics, Up-Side-Down, with Black Handles (Element 1k); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS11 8-pole: 8/8/8/8 8-pole block of Front-Connected W3TS Switches with (4) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; 600 Volts 30 amp.
W3TS-08-TS11-B 8-pole: B8/B8/B8/B8 C 8-pole block of Back-Connected W3TS Switches with (4) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-08-TS12-DR 8-pole: 8/8/8/1U/1U DR 8-pole block Front-Connected W3TS Switches with (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #8), and (2) Basics, Up-Side-Down, with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS13&C 8-pole: 4/4/4/4/4/4/4/4 C 8-pole block of Front-Connected W3TS Switches with (8) independent Short-Circuiting Switches with Black Handles (Element #4); Barriers; Cover; 600 Volts 30 amp.
W3TS-08-TS14-DR 8-pole: 4/4 G 4/4 G 4/4 G 4/4 G CB DR 8-pole block of Front-Connected W3TS Switches with (4) pair of Short-Circuit Assembly Switches with Black Handles (Element #4), each pair Ganged and all connected with an 8-pole Common Bar; Barriers; DIN Rail Clips; 600 Volt, 30 amp.
W3TS-08-TS15-B 8-pole: B3k/B14/B6/B4 C 8-pole block of Back-Connected W3TS Switches with Ganged 3-pole Basics with Black Handles (Element #3k), (1) Blank Space (Element #14), (1) Ganged 3-pole Short Circuit Current Assembly with Black Handles connected with a Common Bar (Element #6), and (1) Short-Circuit Current Assembly with Black Handle (Element #4); Barriers; Cover; 600 Volt 30 amp.
W3TS-08-TS2-DR 8-pole: 4/4/4/4/4/4/4/4 DR 8-pole block of Front-Connected W3TS Switches with (8) independent Short-Circuiting Switches with Black Handles (Element #4); Barriers; DIN Rail clips; 600 Volts 30 amp.
W3TS-08-TS2r-DR 8-pole: 4r/4r/4r/4r/4r/4r/4r/4r DR 8-pole block of Front-Connected W3TS Switches with (8) independent Short-Circuiting Switches with Red Handles (Element #4r); Barriers; DIN Rail clips; 600 Volts 30 amp.
W3TS-08-TS3&C-CB8 8-pole: 4/4/4/4/4/4/4/4 CB C 8-pole block of Front-Connected W3TS Switches with (8) Short-Circuiting Switches - Black Handles - (Element #4) all connected with 8-pole Common Bar; End Barriers; Cover; 600 Volts 30 amp.
W3TS-08-TS3-DR 8-pole: 4/4/4/4/4/4/4/4 CB DR 8-pole block of Front-Connected W3TS Switches with (8) Short-Circuiting Switches - Black Handles - (Element #4) all connected with Common Bar; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS4-DR 8-pole: 13/13/13/13/13/13/13/13 DR 8-pole block of Front-Connected W3TS Switches consisting of (8) Through Bars (Element #13); Barriers; Din Rail clips; 600 Volts 30 amp.
W3TS-08-TS5 8-pole: 4/4/4/4/4/4/4/4 NK CB G 8-pole block of Front-Connected, NO KNOB, W3TS Switches with (8) Short-Circuiting Switches - Black Handles - (Element #4) all connected with Common Bar, all Ganged together; Barriers; 600 Volts 30 amp.
W3TS-08-TS5&C 8-pole: 4/4/4/4/4/4/4/4 CB G C 8-pole block of Front-Connected W3TS Switches with (8) Short-Circuiting Switches - Black Handles -(Element #4), all connected with Common Bar, and all Ganged together; End Barriers; Cover; 600 Volts 30 amp.
W3TS-08-TS5-DR 8-pole: 4/4/4/4/4/4/4/4 CB G DR 8-pole block of Front-Connected W3TS Switches with (8) Short-Circuiting Switches - Black Handles - (Element #4), all connected with a Common Bar, and all Ganged together; End Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-08-TS5-DR&C 8-pole: 4/4/4/4/4/4/4/4 CB G DR C 8-pole block of Front-Connected W3TS Switches with (8) Short-Circuiting Current Switches - Black Handles - (Element #4), all connected with a Common Bar, and all Ganged together; End Barriers; DIN Rail Clips; Cover; 600 volts 30 amp.
W3TS-08-TS6 8-pole: 4/4 CB 4/4 CB 4/4 CB 4/4 CB 8-pole block of Front-Connected W3TS Switches with (4) pair of Short-Circuiting Assemblies - Black Handles - (Element #4), with each pair connected by a 2-pole Common Bar; Barriers; 600 Volt, 30 amp.
W3TS-08-TS7-DR-G8&C 8-pole: 4/4/4/4/4/4/4/4 G DR C 8-pole block of Front-Connected W3TS Switches with (8) Short-Circuiting Current Switches - Black Handles - (Element #4), all Ganged together; Barriers; DIN Rail Clips; Cover; 600 volts 30 amp.
W3TS-08-TS8-G4 8-pole: 1/1/1/1 G 13/13/13/13 8-pole block of Front-Connected W3TS Switches with (4) Basics with Red Handles (Element #1), all Ganged together, then (4) Through Bar Switches (Element #(13); Barriers; 600 Volts 30 amp.
W3TS-08-Yk-DR-NK 8-pole: 2k/2k/2k/2k NK DR 8-pole block of Front-Connected, NO KNOB, W3TS Switches with (4) Ganged Double-Pole No Safety Knob Basics with Black Handles (Element 2k); Barriers; & DIN Rail Clips; 600Volt 30 amp.
W3TS-08-W-DR 8-pole: DR 5/5/5/5 8-Pole block of Front-Connected W3TS Switches with (4) (Ganged 2-pole Short-Circuiting Assemblies with Common Bar and Black Handles (Element #5); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-08-W 8-pole: 5/5/5/5 8-Pole block of Front-Connected W3TS Switches with (4) Ganged 2-pole Short-Circuiting Assemblies with Common Bar & Black Handles (Element #5); Barriers; 600 Volt 30 amp.
W3TS-08-TS9-G4 8-pole: 1/1/1/1 G 15/15/15/15 8-pole block of Front-Connected W3TS Switches with 4 Basics with Red Handles (Element #1), all Ganged together, then (4) Terminal Blocks (Element #15); Barriers; 600 Volts 30 amp.
NINE POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-09-A 9-pole: 1/1/1/1/1/1/1/1/1 9-pole block of Front-Connected W3TS Switches with (9) Single-Pole Basics with Red Handles (Elements #1); Barriers; 600 Volts 30 amp.
W3TS-09-A-B 9-pole: 1/1/1/1/1/1/1/1/1 C 9-pole block of Back-Connected W3TS Switches with (9) Single-Pole Basics - Red Handles - (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-09-A-DR 9-pole: 1/1/1/1/1/1/1/1/1 DR 9-pole block of Front-Connected W3TS Switches with (9) Single-Pole Basics with Red Handles (Elements #1); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-09-Ak 9-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k 9-pole block of Front-Connected W3TS Switches with (9) Single-Pole Basics with Black Handles (Elements #1k); Barriers; 600 Volts 30 amp.
W3TS-09-Bk-DR-NK 9-pole: 3k/3k/3k NK DR 9-pole block of Front-Connected, NO KNOB, W3TS Switches with (3) Ganged Three-Pole Basics with Black Handles (Element #3k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-09-DI & C 9-pole: 9/1k/1k/1k/1k/1k/1k/1k C 9-pole block of Front-Connected W3TS Switches consisting of (1) Right-Hand Test Jack and Short-Circuiting Assembly with Common Bar and Black Handles (Element #9), followed by (7) Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volts 30 amp.
W3TS-09-mD&C 9-pole: 1/1/1 4/4 CB 4/4 CB 4/4 CB C 9-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles (Element #1), and (3) pair of Short-Circuiting Assemblies with Black Handles (Element #4), each pair connected with Common Bar; Barriers; Cover; 600 Volts 30 amp.
W3TS-09-TS-V-B 9-pole: B1/B1/B1/B8/B8/B8 C 9-pole block of Back-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), and (3) Left-Hand Test Jack & Short-Circuit Assemblies with Common Bar and Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-09-TS1 & C 9-pole: 1U/5/1U/5/1U/5 C 9-pole block of Front-Connected W3TS Switches alternating (3) Upside-down Basics with Red Handles (Element #1) with (3) Ganged Short- Circuiting Current Assemblies with Black Handles (Element #5); Barriers; Cover; 600 Volt 30 amp.
W3TS-09-TS14-DR 9-Pole: 4/4 G 4/4 G 4/4 G 4/4 G 13 CB DR 9-pole block of Front-Connected W3TS Switches with (4) pair of Short-Circuiting Assemblies with Black Handles (Element #4), each pair Ganged, (1) Through Bar Switch (Element #13), all connected with a 9-pole Common Bar; End Barriers; DIN Rail Clips; 600 V
W3TS-09-TS2 9-pole: 3k/2/1k/1k/1k/1k 9-pole block of Front-Connected W3TS Switches with (1) Ganged 3-pole Basic with Black Handles (Element 3k), (1) Ganged 2-Pole Basic with Red Handles (Element #2), and (4) Single-Pole Basics with Black Handles (Element 1k); 600 Volts 30 amp.
W3TS-09-TS3&C-DR 9-pole 4r/4r/4r/1k/1k/1k/4r/4r/4r DR C 9-pole block of Front-Connected W3TS Switches consisting of (3) Short-Circuiting Assemblies with Red Handles(Element 4r), (3) Basics with Black Handles (Element 1k), and (3) Short-Circuiting Assemblies with Red Handles (Element 4r); Barriers; DIN Rail Cl
W3TS-09-TS4 & C 9-pole: 3/8/8/8 C 9-pole block of Front-Connected W3TS Switches with (1) Ganged 3-pole Basic with Red Handles (Element #3), and (3) Left-Hand Current Assemblies with Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover;
W3TS-09-TS4--B 9-pole: B3/B8/B8/B8 C 9-pole block of Back-Connected W3TS Switches with (1) Ganged 3-pole Basic with Red Handles (Element #3), and (3) Left-Hand Test Jack & Short-Circuiting Assemblies with Common Bar and Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-09-TS4-DR & C 9-pole: 3/8/8/8 DR C 9-pole block Front-Connected W3TS Switches with (1) Ganged 3-pole Basic with Red Handles (Element #3), and (3) Left-Hand Current Assemblies with Test Jack & Short-Circuiting Current Assemblies with Common Bar and Black Handles (Element #8); Barriers; DIN
W3TS-09-TS5-DR & C 9-pole: 3/6/6 DR C 9-pole block of Front-Connected W3TS Switches with (1) Ganged 3-pole Basic with Red Handles (Element #3), and (2) 3-pole Short-Current Assemblies with Common Bar and Black Handles (Element #6); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-09-TSX & C 9-pole: 1/1/1/ 12/12/12 C 9-pole block of Front-Connected W3TS Switches consisting of (3) Single-Pole Basics with Red Handles (Element #1), and (3) Right-Hand Single Terminal & Short-Circuiting Current Assemblies with Common Bar and Black Handles (Element #12); Barriers; Cover; 60
TEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-10-A 10-pole: 1/1/1/1/1/1/1/1/1/1 10-pole block of Front-Connected W3TS Switches consisting of (10) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volts 30 amp.
W3TS-10-A&C 10-pole: 1/1/1/1/1/1/1/1/1/1 C 10-pole block of Front-Connected W3TS Switches consisting of (10) Single-Pole Basic Switches with Red Handles (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-A-B 10-pole: B1/B1/B1/B1/B1/B1/B1/B1
/B1/B1 C
10-pole block of Back-Connected W3TS Switches with (10) Single-Pole Potential Basic Switches with Red Handles (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-A-DR 10-pole: 1/1/1/1/1/1/1/1/1/1 DR 10-pole block of Front-Connected W3TS Switches with (10) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-A-DR & C 10-pole: 1/1/1/1/1/1/1/1/1/1 DR C 10-pole block of Front-Connected W3TS Switches with (10) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-10-A-TS1-DR 10-pole: 1/1k/1k/1k G /1k/1k/1k/1k/
1k G DR
10-pole block of Front-Connected W3TS Switches consisting of (4) Basics with (1) Red Handle & (3) Black Handles (Elements #1 & 1k), all Ganged, followed by (6) Basics with (1) Red Handle and (5) Black Handles (Elements #1 & 1k), all Ganged; Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-ABB-B 10-pole: B1/B1/B1/B1/B9/B9/B9 C 10-pole block of Back-Connected W3TS Switches consisting of (4) Red Handled Basics (Element #1), and (3) Right-Hand Current Assemblies with Short-Circuiting Assembly & Test Jack with Common Bar and Black Handles (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Ak&C 10-pole: 1k/1k/1k/1k/1k/1k/1k/1k/
1k/1k C
10-pole block of Front-Connected W3TS Switches with (10) Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Ak-B 10-pole: B1k/B1k/B1k/B1k/B1k/B1k/B1k/B1k
/B1k/B1k C
10-pole: : 10-pole block of Back-Connected W3TS Switches with 10 Single-pole Basics with Black Handles; Cover; 600 Volts 30 amp.
W3TS-10-Ak-CB-DR-&C 10-pole: 1k/1k/1k/1k/1k/1k/1k/1k/
1k/1k CB C
10-pole block of Front-Connected W3TS Switches with (10) Basic Switch Black Handles (Element #1k), connected by a 10-pole Common Bar; Cover; 600 Volt 30 amp.
W3TS-10-Ak-DR 10-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k DR 10-pole block of Front-Connected W3TS Switches with (10) Single-Pole Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-Ak-DR&C 10-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k DR C 10-pole block of Front-Connected W3TS Switches with (10) Single-Pole Basics with Black Handles (Element 1k); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-10-Ark G5-5 10-pole: 1/1/1/1/1 G 1k/1k/1k/1k/1k G 10-pole block of Front-Connected W3TS Switches with (5) Red Handled Basics (Element #1), all Ganged together, and (5) Black Handled Basics (Element 1k), all Ganged together; Barriers; 600 Volt 30 Amp.
W3TS-10-Ark&C 10-pole: 1/1/1/1k/1k/1k/1k/1k/1k/1k C 10-pole block of Front-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), and (7) Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-ArkCB5-5G5-5 10-pole: 1/1/1/1/1 G CB 1K/1K/1K/1K/1K G CB 10-pole block of Front-Connected W3TS Switches with (5) Red Handled Basics (Element #1), all Ganged together connected by a 5-pole Common Bar, and (5) Black Handled Basics (Element 1k), all Ganged together connected by a 5-poleCommon Bar; Barriers; 600 Volt 30 Amp.
W3TS-10-Bk-B 10-pole: B1k/B1k/B1k/B1k/B1k/B1k/B1k/B9
/B1k C
10-pole block of Back-Connected W3TS Switches with (7) Basics with Black Handles (Element #1k), (1) Right-Hand Test Jack & Short Circuit Current Assembly with Common Bar and Black Handles (Element #9), and (1) Basic with Black Handle (Element #1k); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-CG-B 10-pole: B1/B5/B1/B5/B1/B5/B13 C 10-pole block of Back-Connected W3TS Switches alternating (3) Basics -Red Handles with (3) Ganged 2-pole Short-Current Assembly with Common Bar and Black Handles (Element #5) followed by a Through Bar (Element #13); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-E&C 10-pole: 1/9/1/9/1/9/1 C 10-pole block of Front-Connected W3TS Switches, alternating (4) Basics with Red Handles (Element #1) with (3) Right-Hand Test Jack/Short-Circuit Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-E&C-DR 10-pole: C 1/9/1/9/1/9/1 DR C 10-pole block of Front-Connected W3TS Switches, alternating (4) Basics with Red Handles (Element #1) with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-10-E-B 10-pole: B1/B9/B1/B9/B1/B9/B1 C 10-pole block of Back-Connected W3TS Switches, alternating (4) Basics with Red Handles (Element #1) with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-E-DR 10-pole: 1/9/1/9/1/9/1 DR 10-pole block of Front-Connected W3TS Switches, alternating (4) Single-Pole Basics - Red Handles - (Element #1) with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-E-DR&C 10-pole: 1/9/1/9/1/9/1 DR C 10-pole block of Front-Connected W3TS Switches alternating (4) Single-Pole Basics - Red Handles - (Element #1), with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-10-E2&C 10-pole: C 1/8/1/8/1/8/1 C 10-pole block of Front-Connected W3TS Switches, alternating (4) Basics - Red Handles - (Element #1) with (3) Left-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-E2-B 10-pole: B1/B8/B1/B8/B1/B8/B1 C 10-pole block of Back-Connected W3TS Switches, alternating (4) Basics - Red Handles - (Element #1)with (3) Left-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Ek&C 10-pole: 1k/9/1k/9/1k/9/1k C 10-pole block of Front-Connected W3TS Switches, alternating (4) Basics - Red Handles - (Element #1) with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar(Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Ekr&C 10-pole: 1k/9r/1k/9r/1k/9r/1k C 10-pole block of Front-Connected W3TS Switches, alternating (4) Basics - Black Handles - (Element #1k) with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Red Handles & Common Bar (Element #9r); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Erk-DR 10-pole: 1/9/1/9/1/9/1k DR 10-pole block of Front-Connected W3TS Switches, alternating (3) Red Handled Basics (Element #1), and (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), followed by (1) Black Handled Basic (Element #1k); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-Erk-DR&C 10-pole: 1/9/1/9/1/9/1k DR C 10-pole block Front-Connected W3TS Switches alternating (3) Red Handled Basics (Element #1), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and followed by (1) Black Handled Basic (Element #1k); Barriers, DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-10-F-DR&C 10-pole: 9/9/9/1/1/1/1 DR C 10-pole block of Front-Connected W3TS Switches with (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles (Element #9), then (4) basic Switches with Black Handles (Element 1k); Barriers; DIN Rail Clips; Cover; 600 volt 30 amp.
W3TS-10-G 10-pole: 1/5/1/5/1/5/1 10-pole block of Front-Connected W3TS Switches alternating (1) Basic with Red Handle (Element #1), and (1) Ganged 2-pole Short-Circuiting Current Assembly with Common Bar & Black Handles (Element #5); Barriers; 600 Volt 30 amp.
W3TS-10-GA & C 10-pole: 1k/1k/1k/5r/5r/5r/1k C 10-pole block Front-Connected W3TS Switches with (3) Basics with Black Handles (Element #1k), (3) Ganged 2-pole Short-Current Assemblies with Common Bar & Red Handles (Element #5r), and (1) Basic with Black Handle (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-GA 10-pole: 1k/1k/1k/5r/5r/5r/1k 10-pole block Front-Connected W3TS Switches with (3) Basics with Black Handles (Element #1k), (3) Ganged 2-pole Short Circuiting-Current Assemblies with Common Bar & Red Handles (Element #5r), and (1) Basic with Black Handle (Element #1k); Barriers; 600 Volt 30 amp.
W3TS-10-GB-DR&C 10-pole: 1/1/1/5/5/5/1 DR C 10-pole Black of Front-Connected W3TS Switches with (3) Red Handled Basics (Element #1), (3) ganged 2-pole Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #5), and (1) Red Handled Basic (Element #1); Barriers; DIN Rail Clips; & Cover; 600 Volt 30 amp.
W3TS-10-H 10-pole: 1/1/1/1/9/9/9 10-pole block of Front-Connected W3TS Switches consisting of (4) Single-Pole Basics with Red Handles (Element #1), and (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; 600 Volts 30 amp.
W3TS-10-H&C 10-pole: 1/1/1/1/9/9/9 C 10-pole block of Front-Connected W3TS Switches consisting of (4) Single-Pole Basics with Red Handles (Element #1), and (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-H-B 10-pole: B1/B1/B1/B1/B9/B9/B9 C 10-pole block of Back-Connected W3TS Switches consisting of (4) Back-Connected Basics with Red Handles (Element #1k), and (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-Hk&C 10-pole: 1k/1k/1k/1k/9/9/9 C 10-pole block of Front-Connected W3TS Switches consisting of (4) Basics with Red Handles (Element 1k), and (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-J-B 10-pole: B1/B1/B1/B9/B9/B9/B1 C 10-pole block of Back-Connected W3TS Switches consisting of (3) Back-Connected Red Basics (Element 1k), (3) Back-Connected Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (1) Back-Connected Red Basic (Element #1); Barriers; Cover; 600 Volt 30amp.
W3TS-10-J2-B 10-pole: B1/B1/B1/B9/B9/B9/B1k C 10 pole block of Back-Connected W3TS Switches with (3) Red Handled Basics (Element #1), (3) (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (1) Basic with Black Handle (Element 1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-JD&C 10-pole: 9/9/9/9/2 C 10-pole block of Front-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (1) Ganged 2-pole Basic with Red Handles (Element #2); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Jk-B 10-pole: B1k/B1k/B1k/B9/B9/B9/B1k C 10-Pole Block of Back-Connected W3TS Switches consisting of 3 Black Handled Basics (Element 1k), (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (1) Black Handled Basic (Element 1k) Barriers; Cover; 600 Volt 30 amp.
W3TS-10-K-B 10-pole: B1/B9/B9/B9/B9/B1 C 10-pole Block of Back-Connected W3TS Switches consisting of (1) Basic with Red Handle (Element #1), (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (1) Basic with Red Handle (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-Kk-B 10-pole: B1k/B9/B9/B9/B9/B1k C 10-pole Block of Back-Connected W3TS Switches consisting of (1) Basic with Red Handle (Element #1), (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (1) Basic with Red Handles (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-L-B 10-pole: B9/B9/B9/B9/B1/B1 C 10-pole block of Back-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9), and (2) Red Handled Basics (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-N 10-pole: 5/5/5/5/5 10-Pole block of Front-Connected W3TS Switches with (5) pair of Ganged 2-pole Short-Circuiting Assemblies with Common Bar & Black Handles (Element #5), each pair separated with Barriers; 600 Volt 30 amp.
W3TS-10-N-B 10-pole: B5/B5/B5/B5/B5 C 10-Pole block of Back-Connected W3TS Switches with (5) pair of Ganged 2-pole Short-Circuiting Assemblies with Common Bar & Black Handles (Element #5), each pair separated with Barriers; Cover; 600 Volt 30 amp.
W3TS-10-Q 10-pole: 7/7/7/7/7/7/7/7/7/7 10-pole block of Front-Connected W3TS Switches consisting of (10) Test Jack Switches with Black Handles (Element #7); Barriers; 600 Volts 30 amp.
W3TS-10-Q-B 10-pole: B7/B7/B7/B7/B7/B7/B7/B7/B7/B7 10-pole block of Back-Connected W3TS Switches consisting of (10) Test Jack Switches; Barriers; Cover; 600 Volt 30 amp.
W3TS-10-T&C 10-pole: 1/1/1/13/9/9/9 C 10-pole block of Front-Connected W3TS Switches consisting of (3) Basics with Red Handles (Element #1), (1) Through Bar (Element #13), and (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-T2-B 10-pole: B1/B1/B1/B13/B8/B8/B8 C 10-pole block of Back-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), (1) Through Bar (Element #13), and (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Black Handles & Common Bar (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TPC 10-pole: 5/5/5/3/1 C 10-pole Black of Front-Connected W3TS Switches with (3) Ganged 2-pole Short-Circuiting Current Assembly with Common Bar & Black Handles (Element #5), (1) Ganged 3-pole Basic with Red Handles (Element #3), and (1) Single-pole Basic with Red Handle (Element #1) Barriers; Cover; 600V 30 amp.
W3TS-10-TS-Akr&G6-4 10-pole: 1k/1k/1k/1k/1k/1k G 1/1/1/1 G 10-pole block of Front-Connected W3TS Switches consisting of (6) Basics with Black Handles (Element #1k), Ganged, and then (4) Basic with Red Handles (Element #1), Ganged; Barriers; 600 Volt 30 amp.
W3TS-10-TS-C&C 10-pole: 7r/7r/7r/7r/8/8/8 C 10-pole block of Front-Connected W3TS Switches with (4) Test Jacks with Red Handles (Element #7r) followed by (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS-C-B 10-pole: B7r/B7r/B7r/B7r/B8/B8/B8 C 10-pole block of Back-Connected W3TS Switches consisting of (4) Test Jacks with Red Handles (Element #7r), and (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS-D&C 10-pole: 7r/9/7r/9/7r/9/7r C 10-pole Block of Front-Connected W3TS Switches alternating 4 Test Jacks with Red Handles (Element #7r), and (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS-E&C 10-pole: 8/8/8/8/8 C 10-pole block of Front-Connected W3TS Switches made of (5) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-F&C 10-pole: 7/1/7/1/7/1/7/1/7/1 C 10-pole block of W3TS Switches consisting of (5) Test Jacks with Black Handles (Element #7), alternating with (5) Basics with Red Handles (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS-G&C 10-pole: 1/1/8/8/8/8 C 10-pole block of Front-Connected W3TS Switches consisting of (2) Basics with Red Handles (Element #1), followed by (4) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-H&C 10-pole: 1/1/1/1/8/1/1/1/1 C 10-pole block of Front-Connected W3TS Switches with (4) Basics with Red Handles (Element #1), (1) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8), and (4) Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-J&C 10-pole: 1/1/1/8/8/8/1 C 10-pole block of Front-Connected W3TS Switches made of (3) Basics with Red Handles (Element #1), (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8), and (1) Basic with Red Handle (Element #1); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-X-DR&C 10-pole: 3/1k/1k/1k/1k/1k/1k/1k DR C 10-pole block of Front-Connected W3TS Switches with 1 Ganged 3-pole Basic with Red Handle (Element #3), and (7) Basics with Black Handles (Element 1k); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-10-TS-T-DR 10-pole: 9/9/9/9/7r/7r DR 10-pole block of Front-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Test Jacks with Red Handles (Element 7r); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-TS-S-DR 10-pole: 7r/7r/7r/13/9/9/9 DR 10-pole block of Front-Connected W3TS Switches with (3) Test Jacks with Red Handles (Element 7r), (1) Through Bar (Element #13), and (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-TS-Rk-B 10-pole: B1k/B9/B9/B9/B1k/B1k/B1k C 10-pole Block of Back-Connected W3TS Switches consisting of (1) Basic with Black Handle (Element 1k), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (3) Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-P&C 10-pole: 1k/1k/1k/1k/2/2/2 C 10-pole block of Front-Connected W3TS Switches made of (4) Basics with Red Handles (Element #1), and (3) Ganged Double-Pole Basic with Red Handles (Element #2); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-Ng&C 10-pole: 1/1/1/7g/9/9/9 C 10-pole Block of Front-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), (1) Test Jack with Green Handle (Element #7g), and (3) Right-Hand Test Jack Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-N&C 10-pole: 1/1/1/7/9/9/9 C 10-pole Block of Front-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), (1) Test Jack switch with Black Handle (Element #7), and (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-Mk 10-pole: 8/8/8/1k/1k/1k/1k 10-pole block of Front-Connected W3TS Switches made of (3)Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8), then (4) Basics with Black Handles (Element 1k); Barriers; 600 Volt 30 amp.
W3TS-10-TS-M-B 10-pole: B8/B8/B8/B1/B1/B1/B1 10-pole block of Back-Connected W3TS Switches with (3) Left-Hand Test Jack & Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #8), then (4) Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-L-B 10-pole: B1/B8/B8/B8/B8/B1 C 10-pole Block of Back-Connected W3TS Switches consisting of (1) Basic with Red Handles (Element #1), (4) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8), and (1) Basic with Red Handle (Element #1); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS-K-B 10-pole: B1/B1/B1/B1/B8/B8/B8 C 10-pole block of Back-Connected W3TS Switches with (4) Basics with Red Handles (Element 1k), (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-K&C 10-pole: 1/1/1/1/8/8/8 C 10-pole block of Front-Connected W3TS Switches made of (4) Basics with Red Handles (Element #1), (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS-Jk-DR 10-pole: 1k/1k/1k/8/8/8/1k DR 10-pole block of Front-Connected W3TS Switches made of (3) Basics with Black Handles (Element #1k), (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8), and (1) Basic with Black Handle (Element #1k); Barriers; Din Rail Clips; 600 Volt 30 amp.
W3TS-10-TS-J-DR 10-pole: 1/1/1/8/8/8/1 DR 10-pole block of Front-Connected W3TS Switches made of (3) Basics with Red Handles (Element #1), (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8), and (1) Basic with Red Handle (Element #1); Barriers; Din Rail Clips; 600 Volt 30 amp.
W3TS-10-Yk-DR-NK 10-pole: 2k/2k/2k/2k/2k NK DR 10-pole block of Front-Connected NO KNOB W3TS Switches with (5) Ganged Double-Pole Basics with Black Handles (Element 2k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-10-Y-DR 10-pole: 2/2/2/2/2 DR 10-pole block of Front-Connected W3TS Switches with (5) Ganged Double-Pole Basics with Red Handles (Element #2); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-10-Y 10-pole: 2/2/2/2/2 10-pole block of Front-Connected W3TS Switches with (5) Ganged Double-Pole Basics with Red Handles (Element #2); Barriers; 600 Volts 30 amp.
W3TS-10-Wrk-B 10-pole: B9/B9/B9/B1/B1/B1k/B1k 10-pole block of Back-Connected W3TS Switches with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (2) Basics with Red Handles (Element #1), and (2) Basics with Black Handles (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-W-B 10-pole: B9/B9/B9/B1k/B1k/B1k/B1k C 10-pole block of Back-Connected W3TS Switches with (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (4) Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-V-B 10-pole: B1/B4 CB B1k/B1k/B4 CB B1k/B1k/B4 CB B1k/B1k 10-pole block of Back-Connected W3TS Switches with (1) Basic with Red Handle (Element #1), then alternate (3) Short Circuiting Assemblies with Black Handles (Element #4), Linked by Common Bar to (3) Basics with Black Handles (Element #1k), and (3) individual Basics with Black Handles (Element #1k); Barriers/ Cover; 600Volt 30 amp.
W3TS-10-TS9-B 10-pole:B1/B1/B1/B4/B4/B4/B4/B1 C 10-pole block of Back-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), (6) Short-Circuiting Assemblies with Black Handles (Element #4), and (1) Basic with Red Handle (Element #1)Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS8-B 10-pole: B1k/B1k/B1k/B8/B8/B8/B7 C 10-pole block of Back-Connected W3TS Switches with (3) Black-Handled Basics (Element 1k), (3) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8), and (1) Test Jack with Black Handle (Element #7); Barriers; & Cover; 600 Volt 30 amp.
W3TS-10-TS7-B 10-pole BC B8/B8/B8/B8/B8 C 10-pole block of Back-Connected W3TS Switches with (5) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS6&C 10-pole: 3/13/5/5/5 C 10-pole block of Front-Connected W3TS Switches with (1) Ganged 3-pole Basic with Red Handles (Element #3), (1) Through Bar (Element #13), and (3) Ganged 2-pole Short-Circuiting Assemblies with Common Bar and Black Handles (Element #5); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS5-B 10-pole: B2k/B3k/B1k/B1k/B1k/B2 C 10-pole block of Back-Connected W3TS Switches with (1) Ganged 2-pole Basic with Black Handles (Element 2k), (1) Ganged 3-pole Basic with Black Handles (Element #3k), (3) Basics with Black Handles (Element 1k) and (1) Ganged 2-pole Basic with Red Handles (Element #2); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS4-B 10-pole: B8/B8/B8/B8/B2 C 10-pole block of Back-Connected W3TS Switches with (4) Left-Hand Current Assembly with Short-Circuit/Test Jack Current Assemblies with Black Handles (Element #8), and (1) 2-pole Ganged Basic with Red Handles (Element #2); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS3-B 10-pole: B2k/B3k/B1k/ B1k/B1k/B1k C 10-pole block of Back-Connected W3TS Switches with Ganged 2-pole Basic - Black Handles (Element #2k), Ganged 3-pole Basic -Black Handles (Element #3k, and (4) Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volts 30 amp.
W3TS-10-TS2-Ark&G4-6 10-pole: 1K/1K/1K/1K/1K/1K G 1/1/1/1 G 10-pole block Front-Connected W3TS Switches with (6) Basics with Black Handles (Element #1k), Ganged, then (4) Basics with Red Handles (Element #1), Ganged; Barriers; 600 Volt 30 amp.
W3TS-10-TS2-Akr-G5-5 10-pole: 1k/1k/1k/1k/1k G 1/1/1/1/1 G 10-pole block of Front-Connected W3TS Switches with (5) Basics with Black Handles (Element 1k), all Ganged together, then (5) Basics with Red Handles (Element #1), all Ganged together; Barriers; 600 Volt 30 amp.
W3TS-10-TS13&C 10-pole: 2k/2k/2k/14/1k/1k/1k C 10-pole Block of Front-Connected W3TS Switches with (3) 2 pole Basics Ganged with Black Handles (Element 2K), (1) Blank Space (Element #14), and (3) 1-pole Basics with Black Handles (Element 1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-10-TS12-DR 10-pole: 13/13/13/13/13/13/13/13/13/13 DR 10-pole block of Front-Connected W3TS Switches consisting of (10) Through Bars (Element #13); Barriers; DIN Rail Clips; 600 volts 30 amp.
W3TS-10-TS11-DR&C 10-pole: 7r/7r/7r/7r/8/8/8 DR C 10-pole block of Front-Connected W3TS Switches with (4) Test Jacks with Red Handles (Element #7r), and (3) Left-Hand Test Jack & Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-10-TS10-D 10-pole: 1/1/1/9/1/1/9/1 10-pole block of Front-Connected W3TS Switches with (3) Basics with Red Handles (Element #1), (1) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), 2 Basics with Red Handles (Element #1), (1) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (1) Basic with Red Handle (Element #1); Barriers; 600 Volts 30 amp.
W3TS-10-TS10 10-pole: 1k/1k/1k/1k/5/5/5 10-pole block Front-Connected W3TS Switches with (4) Basics with Black Handles (Element #1k), and (3) Ganged 2-pole Short-Circuit Current Assemblies with Common Bar & Black Handles (Element #5); Barriers; 600 Volt 30 amp.
ELEVEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-11-TS-D 11-pole: 1/1/1/9/9/9/9 11-pole block of Front-Connected W3TS Switches with (3) Single-Pole Basics with Red Handles (Element #1), and (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; 600 Volt 30 amp.
W3TS-11-TS-F-DR&C 5r/1k/5r/1k/5r/1k/14/1k DR C 11-pole block of Front-Connected W3TS Switches with (1) Ganged 2-pole Short-Circuiting Assembly with Red Handle (Element #5r) Alternating with (1) Basic with a Black Handle (Element #1k) for three instances, and then a Blank Space (Element #14), followed by a Basic with Black Handle (Element 1k); Barriers; Din Rail Clips; Cover; 600 Volt 30 amp.
W3TS-11-TS-J3-B 11-pole: B1/B1/B1/B9/B9/B9/B1k/B1k C 11-pole block of Back-Connected W3TS Switches with (3) Red Handled Basics (Element #1), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Black Handled Basics (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-11-TS-J3-DR 11-pole: 1/1/1/9/9/9/1k/1k DR 11-pole block of Front-Connected W3TS Switches with (3) Red Handled Basics (Element #1), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Black Handled Basics (Element #1k); Barriers; DIN Rail Clips; 600 Volts 30 amp.
W3TS-11-TS-K-DR 11pole: 1k/1k/13/1k/1k/1k/1k/13/1k/1k/13 DR 11-pole block of Front-Connected W3TS Switches with (2) Basic with Black Handles (Element #1k), (1) Through Bar (Element #13), (4) Basics with Black Handles (Element #1l), (1) Through Bar (Element #13), (2) Basics with Black Handles (Element #1k), and (1) Through Bar (Element #13); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-11-TS14-DR 11-pole: 4/4G 4/4G 4/4G 4/4G 4/4G 13 CB DR 11-pole block of Front-Connected W3TS Switches with (5) pairs of Short-Circuiting Assemblies with Black Handles (Element #4), each pair Ganged, (1) Through Bar (Element #13) all connected with an 11-pole Common Bar; Barriers; DIN Rail Clips; 600 Volt, 30 amp.
TWELVE POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-12-A 12-pole: 1/1/1/1/1/1/1/1/1/1/1/1 12-pole Block of Front-Connected W3TS Switches made of (12) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volt 30 amp.
W3TS-12-A&C 12-pole: 1/1/1/1/1/1/1/1/1/1/1/1 C 12-pole Block of Front-Connected W3TS Switches consisting of (12) Single-Pole Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp.
W3TS-12-A-DR 12-pole: 1/1/1/1/1/1/1/1/1/1/1/1 DR 12-pole Block of Front-Connected W3TS Switches consisting of (12) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-12-Ak&C 12-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k C 12-pole Block of Front-Connected W3TS Switches consisting of (12) Single-Pole Basics with Black Handles (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-12-Ak-DR 12-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k DR 12-pole Block of Front-Connected W3TS Switches consisting of (12) Single-Pole Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-12-Ak-DR-G12&C 12-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k G DR C 12-pole Block of Front-Connected W3TS Switches with (12) Single-Pole Basics with Black Handles (Element #1k), all Ganged together; Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-12-Bk-DR-NK 12-pole: 2k/2k/2k/2k/2k/2k NK DR 12-pole block of Front-Connected NO KNOB W3TS Switches consisting of (6) #2k Ganged Double-Pole Basics with Black Handles (Element #2k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-12-D&C 12-pole: 9/9/9/9/9/9 C 12-pole block of Front-Connected W3TS Switches made of (6) #9 Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; Cover; 600 Volts 30 amp.
W3TS-12-D-DR 12-pole: 9/9/9/9/9/9 DR 12-pole block of Front-Connected W3TS Switches consisting of (6) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; DIN Rail clips; 600 Volts 30 amp.
W3TS-12-E 12-pole: 1/9/1/9/1/9/1/9 12-pole block of Front-Connected W3TS Switches starting with (1) Single-Pole Basic with Red Handle (Element #1), and alternating with (1) Right-Hand Test Jack/Short-Circuiting Current Assembly with Common Bar & Black Handles (Element #9); Barriers; 600 Vo
W3TS-12-E&C 12-pole: 1/9/1/9/1/9/1/9 C 12-pole block of Front-Connected W3TS Switches start with (1) Single-Pole Basic with Red Handle (Element #1), and alternating with (1) Right-Hand Test Jack/Short-Circuiting Current Assembly with Common Bar & Black Handles (Element #9); Barriers; Cover; 60
W3TS-12-E-B 12-pole: B1/B9/B1/B9/B1/B9/B1/B9 C 12-pole block of Back-Connected W3TS Switches starting with (1) Single-Pole Basic with Red Handle (Element #1), and alternating with (1) Right-Hand Test Jack/Short-Circuiting Current Assembly with Common Bar & Black Handles (Element #9); Barriers; Cover;
W3TS-12-Gr&C 12-pole: 5r/5r/5r/5r/5r/5r C 12-pole block of Front-Connected W3TS Switches with (6) Ganged 2-pole Short Circuiting Assemblies with Common Bar and Red Handles (Element #5r); Barriers; Cover; 600 Volts 30 amp.
W3TS-12-Gr-DR & C 12-pole: 5r/5r/5r/5r/5r/5r DR C 12-pole block of Front-Connected W3TS Switches with (6) Ganged 2-pole Shortcut Assembly with Common Bar and Red Handles (Element #5r); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-12-TS-D & C 12-pole: 8/8/8/8/8/8 C 12-pole block of Front-Connected W3TS Switches made of (6) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-12-TS-D-B 12-pole: B8/B8/B8/B8/B8/B8 C 12-pole block of Back-Connected W3TS Switches made of (6)Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volts 30 amp.
W3TS-12-TS-F&C 12-pole:7/1/7/1/7/1/7/1/7/1/7/1 C 12-pole block of Front-Connected W3TS Switches starting with (1) Test Jack with Black Handle (Element #7) and alternating (1) Basic with Red Handle (Element #1) Barriers; Cover; 600 Volt 30 amp.
W3TS-12-TS-J 12-pole 1/1/1/1/9/9/9/9 12-pole block of Front-Connected W3TS Switches with (4) Single-Pole Basics with Red Handles (Element #1), and (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; 600 Volt, 30 amp.
W3TS-12-TS-M 12-pole 13/1/1/1/9/9/9/9 12-pole block of Front-Connected W3TS Switches with (1) Through Bar (Element #13), (3) Basics with Red Handles (Element #1), and (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; 600 Volt,
W3TS-12-TS-N 12-pole: 13/13/13/13/13/13/13/13/13/13/13/13 12-pole block of Front-Connected W3TS Switches consisting of (12) Through Bars (Element #13); Barriers; 600 Volts 30 amp.
W3TS-12-TS-P&C 12-pole: 1k/1k/1k/1k/9/9/9/1/1 C 12-pole block of Front-Connected W3TS Switches consisting of (4) Basics with Black Handles (Element #1k), (3)Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Basics with Red Handles (Element #1
W3TS-12-TS1-DR&C 12-pole: 3/3/6/6 DR C 12 pole block of Front-Connected W3TS Switches with (2) Ganged 3-Pole Basic with Red Handles (Element #3), and (2)Ganged 3-pole short Current Assemblies with Common Bar and Black Handles (Element #6); Barriers; DIN Rail Clips; Cover; 600 Volts 30 amp.
W3TS-12-TS2-DR&C 12-pole: 6r/6/6/6 DR C 12 pole block of Front-Connected W3TS Switches consisting of (1) Ganged 3-pole Short-Circuiting Assembly with Red Handles and Common Bar (Element #6r), and (3) Ganged 3-pole Short-Circuiting Current Assemblies with Black Handles and Common Bar; Barriers
W3TS-12-TS3-DR&C 12-pole: 11/11/11/11/11/11 DR C 12 pole block of Front-Connected W3TS Switches with (6) Left-Hand Single Terminal and Short Circuiting Assemblies with Black Handles and Common Bar; Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-12-TS4-E&C 12-pole: 1/9/1/9/1/9/1/2k C 12-pole block of Front-Connected W3TS Switches consisting of (1) Basic with Red Handle (Element #1) alternating with (1) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), 3 times, then (1) Basic with Re
W3TS-12-TS5-B 12-pole: B1/B1/B5/B5/B5/B1k/B1k/B1k/B1k C 12-pole block of Back-Connected W3TS Switches with (2) Single-Pole Basic with Red Handles (Element #1), (3) Ganged 2-pole Short-Circuiting Assemblies with Common Bar and Black Handles (Element #5) and (4) Single Pole Basics with Black Handles (Element #1
W3TS-12-U 12-pole: 1/1/1/1/1/1/9/9/9 12-pole block of Front-Connected W3TS Switches with (6) Single-Pole Basics with Red Handles (Element #1), and (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; 600 Volt, 30 amp.
THIRTEEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-13-A&G 13-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1 G 13-pole Block of W3TS Front-Connected Switches made of (13) Single-Pole Basics with Red Handles (Element #1), all Ganged together; Barriers; 600 Volt 30 amp.
W3TS-13-A 13-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1 13-pole Block of W3TS Front-Connected Switches made of (13) Single-Pole Basics with Red Handles; Barriers; 600 Volt 30 amp.
W3TS-13-TS1-DR & C 13-pole: 1/1y/1b/1/1y/1b/1/1y/1b/1/1y/1b/13 DR C 13-pole: 13-pole block of Front-Connected W3TS with 12 Single Pole Basics alternating Red, Blue, and Yellow Handles (Elements 1, 1y, 1b), finishing with (1) Through Bar (Element #13); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
FOURTEEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-14-A-DR 14-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1 DR 14-pole block of Front-Connected W3TS Switches with (14) Basic Switches with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-14-Ak-DR & C 14-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k DR C 14-pole block of Front-Connected W3TS Switches consisting of (14) Single-pole Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-14-BO-B 14-pole: B9/B9/B9/B9/B1/B1/B1/B1/B1/B1 C 14-pole block of Back-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (6) Single-pole basics with Red Handles (Element #1)/ Barriers; Cover; 600 Volt 30 amp.
W3TS-14-TS-Crk 14-pole: 1/1/1/1/1/1/1/1/1/1/2k/2k 14-pole block of Front-Connected W3TS Switches consisting of (10 Single-pole basics with Red Handles (Element #1), and (2) Double-pole Ganged Basics with Black Handles (Element #2k); Barriers; 600 Volt 30 amp.
W3TS-14-TS-E&C 14 pole: 5r/5y/5b/5g/1r/1y/1b/1g C 14-pole block Front-Connected W3TS Switches consisting of (4) Ganged 2-Pole Short-Circuiting Assemblies with Common Bar with Red , Yellow, Blue and Green Handles (Elements # 5r, 5y, 5b & 5g ), (4) Ganged 2-pole, and (6) Single-pole Basics with Red, Yellow, Blue, & Green Handles (Elements #1r,1y,1b & 1g);Barriers; Cover 600Volt30amp
W3TS-14-TS-F&C 14-pole: 1/1/1/1/8/8/8/8/1k/1k C 14-pole block of Front-Connected W3TS Switches with (4) Single-pole Basics with Red Handles (Element #1), (4) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8), and (2) Single-pole Basics with Black Handles (Element #1k); Barriers; Cover; 600 Volt, 30 amp.
W3TS-14-TS-F-DR & C 14-pole: 1/1/1/1/8/8/8/8/1k/1k DR C 14-pole block Front-Connected W3TS Switches with (4) Single Pole Basics with Red Handles (Element #1), (4) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8), and (2) Single-pole Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-14-TS-J-B 14-pole: B1/B1/B1/B1/B1/B1/B8/B8/B8/B8 C 14-pole block of Back-Connected W3TS Switches with (6) Single-pole Basics with Black Handles (Element #1k), (4) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8); Barriers; Cover; 600 Volt 30 amp.
W3TS-14-TS-J-DR&C 14-pole: 1/1/1/1/1/1/8/8/8/8 DR C 14-pole block of Front-Connected W3TS Switches with (6) Single-pole Basics with Red Handles (Element #1), and (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-14-TS2-DR 14-pole: 13/13/13/13/13/13/13/13/13/13/13/13/13/13 DR 14-pole block of Front-Connected W3TS Switches consisting of (14)Through Bars (Element #13); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-14-TS4-B 14-pole: B9/B9/B9/B9/B1/B1/B1/B1/B1k/B1k C 14-pole block of Back-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole Basics with Red Handles (Element #1), and (2) Single-pole Basics with Black Handles (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-14-W-B 14-pole:B9/B9/B9/B9/B9/B9/B1/B1 C 14-pole block of Back-Connected W3TS Switches with (6) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Single-pole Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp.
FIFTEEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-15-TS14-DR 15-pole: 7G7/7G7/7G7/G7G/7G7/7G7/7G7/13 DR 15-pole block of Front-Connected W3TS Switches with (7) pair of Short-Circuiting Assemblies with Black Handles (Element #4), each pair Ganged, and (1) Through Bar (Element #13), all connected by a 15-pole Common Bar; Barriers; DIN Rail Clips; 600 Volt, 30 amp.
W3TS-15-TS4-B 15-pole: B9/B9/B9/B9/B1/B1/B1/B1/B1k/B1k/B1k C 15-pole block of Back-Connected W3TS Switches consisting of (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole Basics with Red Handles (Element #1), and (3) Single-pole Basics with Black Handles; Barriers; Cover; 600 Volt 30 amp.
SIXTEEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-16-A 16-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 16-pole block of Front-Connected W3TS Switches consisting of (16) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volt, 30 amp.
W3TS-16-A-DR 16-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 DR 16-pole block of Front-Connected W3TS Switches consisting of (16) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-16-Ak-DR 16-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k DR 16-pole block of Front-Connected W3TS Switches consisting of (16) Single-pole basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-16-F-DR&C 16-pole: 1/1/1/1/9/9/9/9/9/9 DR C 16-pole block of Front-Connected W3TS Switches consisting of (4) Single-pole Basics with Red Handles (Element #1), and (6) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-16-TS-P&C 16-pole: 1k/1k/1k/1k/8/8/8/1/1/1/1/1/1 C 16-pole block of Front-Connected W3TS Switches consisting of (4) Single-pole basics with Black Handles (Element #1k), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (6) Single-pole Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp.
W3TS-16-TS2-DR 16-pole: 7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7 DR 16-pole block of Front-Connected W3TS Switches consisting of (16 Test Jack Switches with Black Handles (Element #7; Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-16-TS3-DE 16-pole: 1/1/1/1k/1k/1k/1k/1k G 1/1/1/1k/1k/1k/1k/1k G 16-pole block of Front-Connected W3TS Switches consisting of (2) sets of Single-pole Basics with (8) in each set to include (3) Red Handled Basics (Element #1) followed by (5) Black Handled Basics (Element #1k),all 8 Ganged in each set; Barriers; 600 volt 30 amp.
W3TS-16-TS4-B 16-pole: B9/B9/B9/B9/B1/B1/B1/B1/B1k/B1k/B1k/B1k C 16-pole block of Back-Connected W3TS Switches consisting of (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole basics with Red Handles (Element #1, and (4) Single-pole Basics with Black Handles (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-16-TS5-B 16-pole: B1k/B1k/B1k/B8/B12/B8/B12/B8/B12/B7 C 16-pole block of Back-Connected W3TS Switches consisting of (3) Single-pole Basics with Black Handles (Element #1k), then alternating (3) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8) with (3) Right-Hand Single Terminal and Short-Circuiting Assemblies with Common Bar & Black Handles (Element #12), and (1) Test Jack Switch with Black Handle (Element #7); Barriers; Cover; 600 Volt 30 amp.
W3TS-16-TS6-B 16-pole: B9/B9/B9/B9/B9/B9/B9/B9 C 16-pole block of Back-Connected W3TS Switches with (8) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; Cover; 600 Volt 30 amp.
W3TS-16-A
SEVENTEEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-17-TS4-B 17-pole B C 4 B9; 4 B1; 5 B1k 17-pole block of Back-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); (4) Basics with Red Handles (Element #1) and (5) Basics with Black Handles (Element #1k); & Cover; 600 Volt 30 amp.
EIGHTEEN POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-18-A 18-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 18-pole block of Front-Connected W3TS Switches consisting of (18) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volt 30 amp.
W3TS-18-A-DR 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 DR 18-pole block of Front-Connected W3TS Switches consisting of (18) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-18-TS4-B 18-pole: B9/B9/B9/B9/B1/B1/B1/B1/B1k/B1k/B1k/B1k/B1k/B1k C 18-pole block of Back-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole Basics with Red Handles (Element #1), and (6) Single-pole Basics with Black Handles; (Element #1k); Barriers; Cover; & 600 Volt 30 amp.
W3TS-18-TS4-B&C 18-pole: 9/9/9/9/1/1/1/1/1k/1k/1k/1k/1k/1k C 18-pole block of Front-Connected W3TS Switches with(4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole Basics with Red Handles (Element #1), and (6) Single-pole Basics with Black Handles (Element #1k); Barriers; Cover; 600 Volt 30 amp.
W3TS-18-TS4-B-DR 18-pole: 9/9/9/9/1/1/1/1/1k/1k/1k/1k/1k/1k DR 18-pole block of Front-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole Basics with Red Handles (Element #1), and (6) Single-pole Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-18-TS4-B-DR & C 18-pole: 9/9/9/9/1/1/1/1/1k/1k/1k/1k/1k/1k DR C 18-pole block of Front-Connected W3TS Switches with (4) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (4) Single-pole Basics with Red Handles (Element #1), and (6) Single-pole Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
TWENTY POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-20-A 20-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 20-pole block of Front-Connected W3TS Switches consisting of (20) Single Pole Basics with Red Handles (Element #1); Barriers; 600 Volt 30 amp.
W3TS-20-A-DR 20-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 DR 20-pole block of Front-Connected W3TS Switches consisting of (20) Single Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-20-A-DR & C 20-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 DR C 20-pole block of Front-Connected W3TS Switches consisting of (20) Single Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; Cover; 600 Volt 30 amp.
W3TS-20-Ak 20-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k 20-pole block of Front-Connected W3TS Switches consisting of (20) Single Pole Basics with Black Handles (Element #1k); Barriers; 600 Volt 30 amp
W3TS-20-Ak&C 20-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k C 20-pole block of Front-Connected W3TS Switches consisting of (20) Single Pole Basics with Black Handles Element #1k): Barriers; Cover; 600 Volt 30 amp.
W3TS-20-TS-Bk 20-pole: 2k/14/2k/14/2k/14/2k/14/2k/14/2k/14/2k 20-pole block of Front-Connected W3TS Switches consisting of (7) Ganged 2-Pole Basics with Black Handles (Element #2k) alternated with (6) Blank Spaces (Element #14); Barriers; 600 Volt 30 amp.
W3TS-20-TS-E-DR 20 pole: 1k/1k/13/1k/1k/1k/1k/1k/13/1k/1k/13/1k/1k/13/1k/1k/1k/1k/1k DR 20-pole block of Front-Connected W3TS Switches consisting of (2) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (5) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (2) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (2) Basics with Black Handles,(1) Through Bar (Element #13), finishing with (5) Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-20-TS-F-DR 20 pole: 1k/1k/1k/13/1k/1k/13/1k/1k/13/1k/1k/13/1k/1k/1k/1k/13/1k/1k DR 20-pole block of Front-Connected W3TS Switches consisting of (3) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (2) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (2) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (2) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13), (4) Basics with Black Handles (Element #1k), (1) Through Bar (Element #13) and (2) Basics with Black Handles (Element #1k); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-20-TS2-DR 20-pole: 2k/2k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1/1/1/1/1/1 DR 20-pole block of Front-Connected W3TS Switches consisting of (2) Ganged Double Pole Basics with Black Handles (Element #2k), (10) Basics with Black Handles (Element #1k), and (6) Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-20-TS3-B 20-pole: B1k/B1k/B1k/B9/B9/B9/B1k/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1 C 20-pole block of Back-Connected W3TS Switches consisting of (3) Basics with Black Handles, (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (1) Basic with Black Handle (Element #1k), and (10) Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 amp
W3TS-20-TS4-B 20-pole: B8/B9/B8/B9/B8/B9/B8/B9/B8/B9 20-pole block of Back-Connected W3TS Switches alternating (5) Left-Hand Short-Circuiting/Test Jack Current Assemblies with Common Bar & Black Handles (Element #8), and (5) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9); Barriers; Cover; 600 Volt 30 amp.
W3TS-20-TS5&C 20-pole: 1k/1k/1k/1k/9/9/9/1/1/9/9/9/1/1 C 20-pole block of Front-Connected W3TS Switches consisting of (4) Single-pole Basics with Black Handles (Element #1), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), (2) Single-pole Basics with Red Handles (Element #1), (3) Right-Hand Test Jack/Short-Circuiting Current Assemblies with Common Bar & Black Handles (Element #9), and (2) Single-pole Basics with Red Handles (Element #1); Barriers; Cover; 600 Volt 30 Amp.
TWENTYFOUR POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-24-A 24-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 24-pole block of Front-Connected W3TS Switches consisting of (24) Single-Pole Basics with Red Handles (Element #1); Barriers; 600 Volt 30 amp.
W3TS-24-A-B 24-pole: B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1/B1 C 24-pole block of Back-Connected W3TS Switches consisting of (24) Single-pole Basics with Red Handles (Element #1)Barriers; Cover; 600 Volt 30 amp.
W3TS-24-A-DR 24-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 DR 24-pole block of Front-Connected W3TS Switches consisting of (24) Single-Pole Basics with Red Handles (Element #1); Barriers; DIN Rail Clips; 600 Volt 30 amp.
W3TS-24-Ak-DR 24-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k DR 24-pole block of Front-Connected W3TS Switches consisting of (24) Single-Pole Basics with Black Handles (Element #1k); Barriers; DIN Rail clips; 600 Volt 30 amp.
W3TS-24-Brk 24-pole: 2rk/2rk/2rk/2rk/2rk/2rk/2rk/2rk/2rk/2rk/2rk/2rk 24-pole block of Front-Connected W3TS Switches consisting of (12) Ganged 2-Pole Basics with 1 Red Handle & 1 Black Handle (Element #2rk); Barriers; 600 Volt 30 amp.
W3TS-24-TS-G 24-pole: 7/7/7/4 G CB 7/7/7/4 G CB 7/7/7/4 G CB 1/1/1/1/1/1/1/1 24-pole block of Front-Connected W3TS Switches consisting of (4) sets of (3) Test Jack Switches with Black Handles (Element #7) & (1) Short-Circuiting Assembly (Element #4),Ganged & connected by a 4-pole Common Bar, followed by (8) Single-pole Basics with Red Handles (Element #1); Barriers; 600 Volt 30 amp.
W3TS-24-TS2-DR 24-pole: 7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7/7 DR 24-pole block of Front-Connected W3TS Switches consisting of (24) Test Jack Switches with Black Handles (Element #7; Barriers; DIN Rail clips; 600 Volt 30 amp.
W3TS-24-TS3 24-pole: 12/12/12/12/1/1/1/1/1/1/1/1/2/2/2/2 24-pole block of Front-Connected W3TS Switches consisting of (4) Right-Hand Single Terminal and Short-Circuiting Assemblies with Common Bar and Black Handles (Element #12), (8) Single-pole Basics with Red Handles (Element #1, and (4) Ganged 2-pole Basics with Red Handles (Element #2); 600 Volts 30 amp.
THIRTY POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-30-TS1r 30-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 30-pole block of Front Connected W3TS Switches consisting of (3) Single-Pole Basic Switches with Red Handles (Element #1); Barriers; 600 Volts 30 amp.
THIRTYFIVE POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-35-A 35-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 35-pole block of Front-Connected W3TS Switches consisting of (35) Single Pole Basics with Red Handles (Element #1); Barriers; 600 Volt 30 amp.
FOURTY POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-40-Ak&C 40-pole: 1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k/1k C 40-pole block of Front-Connected W3TS Switches consisting of (4) Single-Pole Basic Switches with Black Handles (Element #1k); Barriers; Cover; 600 Volts 30 amp.
FIFTY POLE CONFIGURATION
Get Quote Testswitch Part Number Short Description Description
W3TS-50-TS1&C 50-pole: 1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1/1 C 50-pole block of Front Connected W3TS Switches consisting of (50) Single-Pole Basic Switches with Red Handles (Element #1); Barriers; Cover; 600 Volts 30 amp.
FINISH YOUR POLE CONFIGURATION REQUEST
Once you have completed selecting your pole configurations by populating the checkbox by the part number, fillout the short form below and submit your request.
All Rights Reserved | Testswitch, LLC | 2016